Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
687
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C01138
C01138
C01139
C01501
Parameter | Name:
C01138 | L_Transient 1-4: Function
Data type: UNSIGNED_8
Index: 23437
d
= 5B8D
h
From version 04.00.00
Selection of edge evaluation
Selection list
0 High edge
1 Low edge
2 High and low edge
Subcodes
Lenze setting
Info
C01138/1
0: High edge
L_Transient_1
: Function
C01138/2
0: High edge
L_Transient_2
: Function
C01138/3
0: High edge
L_Transient_3
: Function
C01138/4
0: High edge
L_Transient_4
: Function
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01139 | L_Transient 1-4: Pulse duration
Data type: UNSIGNED_16
Index: 23436
d
= 5B8C
h
From version 04.00.00
Setting range
(min. value | unit | max. value)
0.000
s
60.000
Subcodes
Lenze setting
Info
C01139/1
0.000 s
L_Transient_1
: Pulse duration
C01139/2
0.000 s
L_Transient_2
: Pulse duration
C01139/3
0.000 s
L_Transient_3
: Pulse duration
C01139/4
0.000 s
L_Transient_4
: Pulse duration
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1000
Parameter | Name:
C01501 | Resp. to communication error with MCI
Data type: UNSIGNED_8
Index: 23074
d
= 5A22
h
Configuration of monitoring functions for the communication module
Selection list
0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Subcodes
Lenze setting
Info
C01501/1
0: No Reaction
Resp. to MCI connection error
• Response to a communication error of the attached
communication module.
C01501/2
0: No Reaction
Resp. to MCI invalid module
• Response to an unplugged or incompatible
communication module
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1