Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
691
8400 StateLine C | Reference manual
Parameter reference
Parameter list | C02582
Bit 3
Horizontal application
Direction of movement of the axis
• "0"
≡
The axis performs vertical movements.
Gravitational acceleration causes movements.
• "1"
≡
The direction of the axis is horizontal or rotary.
The gravitational acceleration does not cause any
movement.
Bit 4
Feedforward control C2581
From version 11.00.00
Selection of the feedforward control value
• "0"
≡
Automatic selection.
–The torque saved at the last stop is used.
• "1"
≡
Manual selection.
–
bMBrakeStartValue2
= FALSE: The feedforward
control value 1 set in
C02581/4
is used.
–
bMBrakeStartValue2
= TRUE: The feedforward
control value set in
C02581/5
is used.
Bit 5
Feedback monitoring
From version 11.00.00
Activation of status monitoring
• "1"
≡
The
bMBrakeApplied
input for status detection
of the brake (via a switching contact at the brake) is
monitored after the waiting time set in
C02589/3
has
expired.
Bit 6
;
SyncRampe L_NSet_1
From version 11.00.00
Selection of the ramp time for the synchronisation
process to setpoint speed after the brake opening time
has elapsed
Revised behaviour from version 11.00.00:
• "1"
≡
The ramp time of the effective acceleration of
the ramp function generator (
L_NSet_1
) is used
(Lenze setting).
• "0"
≡
As before, the ramp time set in
C02610/1
is used.
Note:
The changeover can be dynamically both via the ramp
parameter and via bit 6.
Bit 7
Reserved
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Parameter | Name:
C02582 | Holding brake: Setting
Data type: UNSIGNED_8
Index: 21993
d
= 55E9
h
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com