8400 StateLine C | Reference manual
Parameter reference
Parameter list | C02859
698
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C02859
C02866
C02867
Parameter | Name:
C02859 | PSM: Activate Lss saturation char.
Data type: UNSIGNED_8
Index: 21716
d
= 54D4
h
From version 10.00.00
Correction via saturation characteristic
Selection list
(Lenze setting printed in bold)
0 Off
1 On
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C02866 | MCTRL: Special settings
Data type: UNSIGNED_8
Index: 21709
d
= 54CD
h
Activation of special functions of the internal motor control
Selection list
0 No
1 Yes
Subcodes
Lenze setting
Info
C02866/1
1: Yes
Motor ident.: Current controller par. C075 C076
From version 06.00.00
Automatic motor data identification
C02866/2
0: No
Motor phase error monitoring before operation
•
From version 11.00.00
Motor phase error monitoring before operation
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Parameter | Name:
C02867 - Identification procedure
Data type: UNSIGNED_8
Index: 21708
d
= 54CC
h
From version 10.00.00
Selection of the identification procedure for motor parameter identification
Automatic motor parameter identification
Selection list
Info
0 automatic
Automatic selection of the optimum identification
procedure:
• For synchronous motors, the extended identification
procedure is always used.
• For asynchronous motors with a rated motor power
of up to 11 kW, the basic identification procedure is
used.
• For asynchronous motors with a rated motor power
of more than 11 kW, the extended identification
procedure is used.
1 standard identification
• Only for asynchronous motors.
• Duration approx. 30 s
2 extended identification
• Stands out due to increased accuracy of the
determined motor parameters.
• Also supports synchronous motors and asynchronous
motors with a power of more than 11 kW.
• Duration approx. 80 s
Subcodes
Lenze setting
Info
C02867/1
0: automatic
Motor parameter identification: Process
;
Read access
;
Write access
;
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com