Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
711
8400 StateLine C | Reference manual
Parameter reference
Table of attributes
C00028
AINx: Input voltage
24547
5FE3
A
1
INTEGER_16
100
;
C00029
AINx: Input current
24546
5FE2
A
1
INTEGER_16
100
;
C00033
AINx: Output value
24542
5FDE
A
1
INTEGER_16
100
;
C00034
AINx: Configuration
24541
5FDD
A
1
UNSIGNED_8
1
;
;
C00036
DC braking: Current
24539
5FDB
E
1
INTEGER_16
100
;
;
C00039
Fixed setpoint x (L_NSet_1 n-Fix)
24536
5FD8
A
15
INTEGER_16
100
;
;
C00050
MCTRL: Speed setpoint
24525
5FCD
E
1
INTEGER_32
1
;
C00051
MCTRL: Actual speed value
24524
5FCC
E
1
INTEGER_32
1
;
C00052
Motor voltage
24523
5FCB
E
1
UNSIGNED_16
1
;
C00053
DC-bus voltage
24522
5FCA
E
1
UNSIGNED_16
1
;
C00054
Motor current
24521
5FC9
E
1
UNSIGNED_16
100
;
C00055
Actual values
24520
5FC8
A
1
INTEGER_16
1
;
C00056
Torque
24519
5FC7
A
2
INTEGER_32
100
;
C00057
Maximum torque
24518
5FC6
E
1
UNSIGNED_32
100
;
C00058
Output frequency
24517
5FC5
E
1
INTEGER_32
100
;
C00059
Appl.: Reference frequency C11
24516
5FC4
E
1
UNSIGNED_32
100
;
C00061
Heatsink temperature
24514
5FC2
E
1
INTEGER_16
1
;
C00062
Interior temperature
24513
5FC1
A
1
INTEGER_16
1
;
C00064
Device utilisation (Ixt)
24511
5FBF
A
3
INTEGER_16
100
;
C00065
Supply voltage 24V
24510
5FBE
E
1
INTEGER_16
10
;
C00066
Thermal motor load (I²xt)
24509
5FBD
E
1
INTEGER_16
100
;
C00070
Vp speed controller
24505
5FB9
A
3
UNSIGNED_16
100
;
;
C00071
Ti speed controller
24504
5FB8
A
3
UNSIGNED_16
10
;
;
C00072
SC: Tdn speed controller
24503
5FB7
E
1
UNSIGNED_16
100
;
;
C00073
Imax/M controller gain
24502
5FB6
A
2
UNSIGNED_16
100
;
;
C00074
Reset time Imax/M controller
24501
5FB5
A
2
UNSIGNED_16
1
;
;
C00075
Vp current controller
24500
5FB4
E
1
UNSIGNED_16
100
;
;
C00076
Ti current controller
24499
5FB3
E
1
UNSIGNED_16
100
;
;
C00079
SC: Settings
24496
5FB0
A
4
UNSIGNED_8
1
;
;
C00080
Override point of field weakening
24495
5FAF
E
1
INTEGER_16
1
;
;
C00081
Rated motor power
24494
5FAE
E
1
UNSIGNED_16
100
;
;
C00082
Motor rotor resistance
24493
5FAD
E
1
UNSIGNED_32
1
;
;
C00083
Motor rotor time constant
24492
5FAC
E
1
UNSIGNED_16
1
;
C00084
Motor stator resistance
24491
5FAB
E
1
UNSIGNED_32
1
;
;
C00085
Motor stator leakage inductance
24490
5FAA
E
1
UNSIGNED_16
100
;
;
C00087
Rated motor speed
24488
5FA8
E
1
UNSIGNED_16
1
;
;
C00088
Rated motor current
24487
5FA7
E
1
UNSIGNED_16
100
;
;
C00089
Rated motor frequency
24486
5FA6
E
1
UNSIGNED_16
1
;
;
C00090
Rated motor voltage
24485
5FA5
E
1
UNSIGNED_16
1
;
;
C00091
Motor cosine phi
24484
5FA4
E
1
UNSIGNED_8
100
;
;
C00092
Motor magnetising inductance
24483
5FA3
E
1
UNSIGNED_16
10
;
;
C00093
Power section ID
24482
5FA2
E
1
UNSIGNED_16
1
;
C00095
Motor magnetising current
24480
5FA0
E
1
UNSIGNED_16
100
;
;
C00097
Rated motor torque
24478
5F9E
E
1
UNSIGNED_32
100
;
C00098
Rated device current
24477
5F9D
E
1
UNSIGNED_16
10
;
C00099
Firmware version
24476
5F9C
E
1
VISIBLE_STRING [12]
;
C00100
Firmware version
24475
5F9B
A
4
UNSIGNED_8
1
;
C00101
Add. acceleration time x
24474
5F9A
A
15
UNSIGNED_32
1000
;
;
C00103
Add. deceleration time x
24472
5F98
A
15
UNSIGNED_32
1000
;
;
C00105
Decel. time - quick stop
24470
5F96
E
1
UNSIGNED_32
1000
;
;
C00106
Auto-DCB: Hold time
24469
5F95
E
1
UNSIGNED_32
1000
;
;
Code
Name
Index
Data
Access
dec
hex
DS
DA
DT
Factor
R
W
CINH