Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
823
8400 StateLine C | Reference manual
Function library
Function blocks | L_NSet_1
Definition of the blocking zones
The subcodes of codes
C00632
and
C00633
can be used to define three zones which are to
be skipped by the output setpoint and which are to be passed as fast as possible by the
ramp function generator.
The example below shows the parameter setting of two blocking zones:
[16-13] Zone masking by means of parameterisable blocking zones
The parameterised blocking zones have the same effect on negative input signals.
A blocking zone is deactivated by entering identical limit values (in our example:
Blocking zone 3).
Parameter
Blocking zone 1
Blocking zone 2
Blocking zone 3
Minimum limit value
C00633/1: 48 %
C00633/2: 138 %
C00633/3: 0 %
Maximum limit value
C00632/1: 104 %
C00632/2: 178 %
C00632/3: 0 %
Blocking zone 1
Blocking zone 2
Output [%]
Input [%]
1
0
199.99
-199.99
-199.99
199.99
C00632/1
C00633/1
48
138
0
1
104
178
C00632/2
C00633/2
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com