Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
L
851
8400 StateLine C | Reference manual
Function library
Function blocks | L_Transient_1
16.1.44.3 Function 2: Evaluate rising and falling signal edges
[16-26] Switching performance for function selection "2: High and low edge"
Functional sequence
1. A signal change (FALSE/TRUE edge or TRUE/FALSE edge) at the
bIn
input sets the
bOut
output to TRUE.
2. After the parameterised pulse duration has elapsed, the
bOut
output is reset to FALSE
unless another signal change has taken place at the
bIn
input.
– In case of another signal change at the input
bIn
, the pulse time restarts to elapse,
i.e. the output
bOut
can be retriggered.
n
Pulse duration
TRUE
FALSE
bOut
t
TRUE
FALSE
bIn
t