FSoE parameter
Parameter
Unit
Safety module
Setting / range
[Default]
Description / note
Test pulse duration output x
µs
SDI16/SDO4
Test pulse duration output0 - Test
pulse duration output3
700 ... 1500
[1000]
SDI8/SDO2
Test pulse duration output0 - Test
pulse duration output1
700 ... 1500
[1000]
Test pulse duration of output x
The digital test pulse output is interrupted for the set duration of every test
pulse. The Safety I/O-module checks whether the digital outputs may turn Null
and whether there are any short circuits to noise voltages on the signal line.
Adapt the test pulse duration to the peripherals you use.
Test frequency input x
Hz
SDI16/SDO4 and SDI16
Test frequency input 0/4 - Test fre-
quency input 11/15
0 ... 25
[25]
SDI8/SDO2
Test frequency input 0/4 - Test fre-
quency input 3/7
0 ... 25
[25]
Test pulse frequency of input x
"0" = no test pulse
Test frequency output x
min-1
SDI16/SDO4
Test frequency output 0 - Test fre-
quency output 3
1 ... 25
[10]
SDI8/SDO2
Test frequency output 0 - Test fre-
quency output 1
1 ... 25
[10]
Test pulse frequency of output x
f
t
f