Lenze · Inverter Drive 8400 motec (PROFINET® option) · DMS 5.0 EN · 02/2019 · TD23
29
6
Commissioning
6.4
Setting the IP configuration
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.4
Setting the IP configuration
The IP configuration is required for addressing the Inverter Drive 8400 motec if communication
between the PC/»Engineer« or the IO controller and the inverter is to be established via PROFINET.
This requires allocation of an IP address, subnet mask, and gateway address.
If no PROFINET network or no IO controller is available yet, you have the following options to
allocate the IP address, subnet mask, and gateway address for the Communication Unit:
•
Setting via the PROFINET configurator of the »Engineer«
•
Setting via codes in the »Engineer«
Note!
• If the IP parameters are assigned by the IO controller via PROFINET or the PROFINET
configurator of the »Engineer«, changes will become effective immediately and are
saved with mains failure protection.
• The assignment of invalid combinations of the IP address, subnet mask, and gateway
address can have the consequence that no connection to PROFINET can be
established.
• In the case of impermissible settings, the red LED
BE
blinks (
),
and the error message
PROFINET: Stack init error [0x01bc6534]
is output.