Appendix
11-12
BA9300SU EN 2.1
11.2.5
Digital frequency cascade - slave - drive
The most important settings (short setup)
Tip!
The following codes are contained in the menu: ” Short Setup / DF slave cas” of the Module 9371
BB or in the menu: ” Short commissioning / Digital frequency slave cascade” of Global Drive Control
or LEMOC 2.
Input motor type (contains all nameplate data of the motor)
C0173
xxx
Enter UG limit (mains voltage)
C0086
xxx
Enter LENZE motor type
Enter maximum motor current
C0022
xxxA
Determine Imax
Enter controller configuration
C0005
7000
Select digital frequency cascade - slave
Speed setpoint settings
C0011
xxx rpm
Determine max. speed
C0032
xxx
Gearbox factor numerator
C0033
xxx
Gearbox factor denominator
C0425
xxx
Adapt encoder constant to the master
C0473/1
xxx
Numerator of the stretch factor
C0533
xxx
Denominator of the stretch factor
Application parameters
C0070
xxx
Vp n controller
C0071
xxx
Tn n-controller
C0254
xxx
Gain of the phase controller
Save parameters
C0003
xxx
Save all parameters
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...