Technical data
3-3
BA9300SU EN 2.1
3.3
Rated data
3.3.1
Types 9321 to 9325
Type
EVS9321-ES
EVS9322-ES
EVS9323-ES
EVS9324-ES
EVS9325-ES
Order No.
EVS9321-ES
EVS9322-ES
EVS9323-ES
EVS9324-ES
EVS9325-ES
Type
EVS9321-CS
EVS9322-CS
EVS9323-CS
EVS9324-CS
EVS9325-CS
Order No.
EVS9321-CS
EVS9322-CS
EVS9323-CS
EVS9324-CS
EVS9325-CS
Mains voltage
V
r
[V]
320 V - 0 %
≤
V
r
≤
528 V + 0 % ;
45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply
V
DC
[V]
460 V - 0 %
≤
V
DC
≤
740 V + 0 %
Mains current with mains filter
Mains current without mains filter
I
r
[A]
1.5
2.1
2.5
3.5
3.9
5.5
7.0
-
12.0
16.8
Ratings for operation at a mains: 3 AC / 400V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW]
0.37
0.75
1.5
3.0
5.5
p
( p
)
P
r
[hp]
0.5
1.0
2.0
4.0
7.5
Output power U, V, W (8kHz*)
S
r8
[kVA]
1.0
1.7
2.7
4.8
9.0
Output power + U
DC
, -U
DC
2)
P
DC
[kW]
2.0
0.75
2.2
0.75
0
Output current (8 kHz*)
I
r8
[A]
1.5
2.5
3.9
7.0
13.0
Output current (16 kHz*)
I
r16
[A]
1.1
1.8
2.9
5.2
9.7
Max. output current (8 kHz*)
1)
I
max8
[A]
2.3
3.8
5.9
10.5
19.5
Max. output current (16 kHz*)
1)
I
max16
[A]
1.7
2.7
4.4
7.8
14.6
Max. standstill current (8 kHz*)
I
08
[A]
2.3
3.8
5.9
10.5
19.5
Max. standstill current (16 kHz*)
I
016
[A]
1.7
2.7
4.4
7.8
14.6
Ratings for operation at a mains: 3 AC / 480V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW]
0.37
0.75
1.5
3.0
5.5
p
( p
)
P
r
[hp]
0.5
1.0
2.0
4.0
7.5
Output power U, V, W (8kHz*)
S
r8
[kVA]
1.2
2.1
3.2
5.8
10.8
Output power + U
DC
, -U
DC
2)
P
DC
[kW]
2.0
0.75
2.2
0.75
0
Output current (8 kHz*)
I
r8
[A]
1.5
2.5
3.9
7.0
13.0
Output current (16 kHz*)
I
r16
[A]
1.1
1.8
2.9
5.2
9.7
Max. output current (8 kHz*)
1)
I
max8
[A]
2.3
3.8
5.9
10.5
19.5
Max. output current (16 kHz*)
1)
I
max16
[A]
1.7
2.7
4.4
7.8
14.6
Max. standstill current (8 kHz*)
I
08
[A]
2.3
3.8
5.9
10.5
19.5
Max. standstill current (16 kHz*)
I
016
[A]
1.7
2.7
4.4
7.8
14.6
Motor voltage
V
M
[V]
0 - 3
×
V
Mains
Power loss (operation with I
ratedx
)
P
loss
[W]
100
110
140
200
260
Power derating
[%/K]
[%/m]
40 °C < T
V
< 55 °C: 2%/K (not UL approved)
1000 m amsl < h
≤
4000 m amsl: 5%/1000m
Weight
m [kg]
3.5
3.5
5.0
5.0
7.5
1)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned
here and 2 minutes base load with 75% I
ratedx
2)
When operated under rated load, the controller can supply this power additionally.
*
Chopper frequency of the inverter (C0018)
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...