Appendix
11-45
BA9300SU EN 2.1
Code
Important
Possible settings
LCD
Code
Important
Choice
Lenze
LCD
C0932
5() NO'F
0
0
Mode 0
1
Mode 1
6
Mode 6
7
Mode 7
8
Mode 8
9
Mode 9
20
Mode 20
21
Mode 21
Homing mode
C0933
5() S5D1R
0
0
Rising trans
1
Falling trans
Reference signal transition
rising transition
falling transition
C0934
5() OGGRFS
0
-2140000000
{1 inc}
2140000000
Home position offset
C0935
5() RPFF'
2.0000
0.0001
{0.0001 % N
max
}
100.0000
Homing speed
C0936
5() 7J
1.00
0.01
{0.01 s}
990.00
T
i
time homing
•
Tir and Tif are identical
C0940
18NF5DSO5
1
-32767
{1}
32767
CONV1 Numerator
C0941
'F1ONJSDSO5
1
1
{1}
32767
CONV1 Denominator
[C0942]
J1
1000
FIXED 0 %
→
Selection list 1
Configuration analog input CONV1
C0943
&
g
-199.99
{0.01 %}
199.99
Display of C0942
C0945
18NF5DSO5
1
-32767
{1}
32767
CONV2 numerator
C0946
'F1ONJ1DSO5
1
1
{1}
32767
CONV2 denominator
[C0947]
J1
1000
FIXED 0 %
→
Selection list 1
Configuration analog input CONV2
C0948
&
g
-199.99
{0.01 %}
199.99
Display of C0947
C0950
18NF5DSO5
1
-32767
{1}
32767
CONV3 numerator
C0951
'F1ONJ1DSO5
1
1
{1}
32767
CONV3 denominator
[C0952]
J1
1000
FIXEDPHI0
→
Selection list 4
Configuration analog input CONV3
C0953
&
g
-32767
{1 rpm}
32767
Display of C0952
C0955
18NF5DSO5
1
-32767
{1}
32767
CONV4 numerator
C0956
'F1ONJ1DSO5
1
1
{1}
32767
CONV4 denominator
[C0957]
J1
1000
FIXEDPHI0
→
Selection list 4
Configuration analog input CONV4
C0958
&
g
-32767
{1 rpm}
32767
Display of C0957
C0960
)81ESJO1
1
1
{1}
3
Function
1
Characteristic 1
2
Characteristic 2
3
Characteristic 3
C0961
W
0.00
0.00
{0.01 %}
199.99
C0962
W
50.00
0.00
{0.01 %}
199.99
C0963
W
75.00
0.00
{0.01 %}
199.99
C0964
W
100.00
0.00
{0.01 %}
199.99
C0965
V
50.00
0.01
{0.01 %}
99.99
C0966
V
75.00
0.01
{0.01 %}
99.99
[C0967]
J1
1000
FIXED0%
→
Selection list 1
Characteristic CURVE1-IN
C0968
&
g
-199.99
{0.01 %}
199.99
Display of C0967
[C0970]
1RFS
1000
FIXED0%
→
Selection list 1
Speed input of the mains failure control
Setpoint path
[C0971]
GD8MS
1000
FIXED0
→
Selection list 2
Input mains failure detected, input for
activation
[C0972]
5FRFS
1000
FIXED0
→
Selection list 2
Reset input mains failure control
[C0973]
D'DPS
1000
FIXED0%
→
Selection list 1
Adaptation of P-gain of the voltage controller
[C0974]
EO1RS
1000
FIXED0%
→
Selection list 1
Adaptation of P-gain of the voltage controller
[C0975]
SI5FRI/'
1000
FIXED0%
→
Selection list 1
Restart protection when the value falls below
the speed threshold
[C0976]
1DES
1000
FIXED0%
→
Selection list 1
Comparison of threshold function
•
Start for V
2
controller
[C0977]
RFS
1000
FIXED0%
→
Selection list 1
Speed start value
[C0978]
'ERFS
1000
FIXED0%
→
Selection list 1
Setpoint DC-bus voltage
C0980
9P
0.500
0.001
{0.001}
31.000
MFAIL Vp (gain)
C0981
71
100
20
{0.1 ms}
2000
MFAIL Tn (adjustment time)
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...