Technical data
3-5
BA9300SU EN 2.1
3.3.3
Types 9326 to 9332
Type
EVS9326-ES
EVS9327-ES
EVS9328-ES
EVS9329-ES
EVS9330-ES
EVS9331-ES
EVS9332-ES
Order No.
EVS9326-ES
EVS9327-ES
EVS9328-ES
EVS9329-ES
EVS9330-ES
EVS9331-ES
EVS9332-ES
Type
EVS9326-CS
EVS9327-CS
EVS9328-CS
Order No.
EVS9326-CS
EVS9327-CS
EVS9328-CS
Mains voltage
a
r
[V]
320 V - 0 %
≤
V
r
≤
528 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply
a
DC
[V]
460 V - 0 %
≤
U
DC
≤
740 V + 0 %
Mains current with mains filter
Mains current without mains filter
I
r
[A]
20.5
-
27.0
43.5
44.0
-
53.0
-
78.0
-
100
-
135
-
Ratings for operation at a mains: 3 AC / 400V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW]
11.0
15.0
22.0
30.0
45.0
55.0
75.0
p
( p
)
P
r
[hp]
15.0
20.5
30.0
40.0
60.0
73.5
100.0
Output power UVW (8 kHz*)
S
r8
[kVA]
16.3
22.2
32.6
40.9
61.6
76.2
100.5
Output power + U
DC
, -U
DC
2)
P
DC
[kW]
0
10
4
0
5
0
0
Output current (8 kHz*)
1)
I
r8
[A]
23.5
32.0
47.0
59.0
89.0
110.0
145.0
Output current (16 kHz*)
1)
I
r16
[A]
15.3
20.8
30.6
38.0
58.0
70.0
90.0
Max. output current (8 kHz*)
I
max8
[A]
35.3
48.0
70.5
88.5
133.5
165.0
217.5
Max. output current (16 kHz*)
I
max16
[A]
23.0
31.2
45.9
57.0
87.0
105.0
135.0
Max. standstill current (8 kHz*)
I
08
[A]
23.5
32.0
47.0
52.0
80.0
110.0
126.0
Max. standstill current (16 kHz*)
I
016
[A]
15.3
20.8
30.6
33.0
45.0
70.0
72.0
Ratings for operation at a mains: 3 AC / 480V / 50Hz/60Hz
Motor power (4-pole ASM)
P
r
[kW]
11.0
18.5
30.0
37.0
45.0
55.0
90.0
p
( p
)
P
r
[hp]
15.0
25.0
40.0
49.5
60.0
73.5
120.0
Output power UVW (8 kHz*)
S
r8
[kVA]
18.5
25.0
37.0
46.6
69.8
87.3
104.0
Output power + U
DC
, -U
DC
2)
P
DC
[kW]
0
12
4.8
0
6
0
6
Output current (8 kHz*)
I
r8
[A]
22.3
30.4
44.7
56.0
84.0
105.0
125.0
Output current (16 kHz*)
I
r16
[A]
14.5
19.2
28.2
35.0
55.0
65.0
80.0
Max. output current (8 kHz*)
1)
I
max8
[A]
33.5
45.6
67.1
84.0
126.0
157.5
187.5
Max. output current (16 kHz*)
1)
I
max16
[A]
21.8
28.8
42.3
52.5
82.5
97.5
120.0
Max. standstill current (8 kHz*)
I
08
[A]
22.3
30.4
44.7
49.0
72.0
105.0
111.0
Max. standstill current (16 kHz*)
I
016
[A]
14.5
19.2
28.2
25.0
36.0
58.0
58.0
Motor voltage
a
M
[V]
0 - 3
×
V
Mains
Power loss
P
loss
[W]
360
430
640
810
1100
1470
1960
Power derating
[%/K]
[%/K]
[%/m]
9326:
at 40 °C < T
a
< 55 °C: 2%/K (not UL approved)
9327 - 9332:
at 40 °C < T
a
< 50 °C: 2.5%/K (not UL approved)
1000 m amsl < h
≤
4000 m amsl: 5%/1000m
Weight
m [kg]
7.5
12.5
12.5
12.5
36.5
59
59
1)
The currents apply to a periodical load cycle with 1 minute overcurrent with the current mentioned
here and 2 minutes base load with 75% I
ratedx
2)
When operated under rated load, the controller can supply this power additionally.
*
Chopper frequency of the inverter (C0018)
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...