Installation
4-1
BA9300SU EN 2.1
4
Installation
4.1
Mechanical installation
4.1.1
Important notes
•
Use the controllers only as built-in devices!
•
If the cooling air contains pollutants (dust, fluff, grease, aggressive gases):
– Take suitable preventive measures , e.g. separate air duct, installation of filters, regular
cleaning, etc.
•
Observe free space!
– You can install several controllers next to each other without free space in a control cabinet.
– Ensure unimpeded ventilation of cooling air and outlet of exhaust air!
– Allow a free space of 100 mm at the top and at the bottom.
•
Do not exceed the ambient temperature permissible during operation.
(
^
3-2)
•
With continuous oscillations or vibrations:
– Check whether shock absorbers are necessary.
Possible mounting positions
Vertically on the control cabinet back panel with mains connections at the top:
•
With enclosed fixing rails or fixing brackets.
(
^
4-2)
•
Thermally separated with external heat sink
– Punching
(
^
4-3)
– ” Cold Plate technique”
(
^
4-6)
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...