Commissioning
5-3
BA9300SU EN 2.1
11.Apply setpoint:
– Apply a voltage > 0 V (max. 10 V) at X6/1, X6/2.
– Do not activate a JOG setpoint (X5/E3 LOW).
12.Check whether the controller is ready for operation:
– When the green LED is flashing:
Controller is ready for operation, continue with 13.
– When green LED is dark and red LED is flashing:
There is a fault. Before proceeding with the commissioning, eliminate the fault (see chapter
9 ” Troubleshooting and fault elimination” ).
13.Enable controller (see Chapter 5.3):
– The green LED is illuminated if a HIGH signal is applied at X5/28 (+13 V ... +30 V) and no
other source of controller inhibit is active.
14.For operation with a fieldbus module, additional settings are necessary
(see Operating Instructions for the fieldbus module used).
The motor will now rotate with the setpoint speed and the selected direction of rotation.
Troubleshooting:
Error
Cause / remedy
Feedback system
•
Motor rotates CCW when viewed to the motor shaft
•
C0060 counts down after controller enable
Feedback system is not connected in-phase
•
Connect feedback system in-phase
Asynchronous motor
Motor
•
rotates at I
max
and half slip frequency
•
does not react on setpoint changes
Motor is not connected in-phase
•
Connect motor in phase at the terminals U V W
Synchronous motor
•
Motor does not follow the setpoint change
•
Imax follows the setpoint in idle running
•
Connect motor in-phase at the terminals U, V, W
•
Motor rotates CCW when viewed to the motor shaft.
The rotor angle (offset of electrical and mechanical
rotor angle) is not correct
•
Make a rotor position adjustment (C0095 = 1). For
this, operate the motor without load.
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...