Configuration
8-1
BA9300SU EN 2.1
8
Configuration
Every practical application demands certain application-specific configurations (programs).
For this, function blocks are available which can be connected for the corresponding application.
The function blocks are linked via codes.
(
^
8-4)
8.1
Predefined configurations
Basic configurations are already defined for standard applications of the controller. These basic
configurations can be selected via code C0005. The signal flow charts for the most important basic
configurations are listed in the appendix.
8.1.1
Working with predefined configurations
To adapt predefined configurations to your application, proceed as follows:
1. Select basic configuration under C0005.
2. Select operating mode under C0005.
(
^
11-15)
3. Configure different signal flow charts, if necessary:
– Integrate or remove function blocks.
(
^
8-4)
– Set parameters for function blocks.
(
^
8-5)
– Change terminal configuration.
Note!
If the signal flow for the basic configuration is changed, e.g. by adding function blocks, C0005 is set
to ” 0” . The message ” COMMON” is displayed.
If only the assignment of the control inputs and outputs is changed, C0005 remains the same. Under
code C0464 an identification is displayed.
Summary of Contents for EVS9321-CS
Page 3: ...Operating Instructions EDB9300UES 00414796 Global Drive 9300 servo ...
Page 21: ...Technical data 3 8 BA9300SU EN 2 1 ...
Page 57: ...Installation 4 36 BA9300SU EN 2 1 ...
Page 73: ...During operation 6 4 BA9300SU EN 2 1 ...
Page 117: ...Troubleshooting and fault elimination 9 10 BA9300SU EN 2 1 ...
Page 119: ...Maintenance 10 2 BA9300SU EN 2 1 ...
Page 188: ...Appendix 11 69 BA9300SU EN 2 1 ...
Page 189: ...Appendix 11 70 BA9300SU EN 2 1 ...