Operating mode S1
Calculation of the required drive power
Calculation
Result
Unit
Output torque
M
r
≥ M
L
/ (k
L
x k
H
)
M
r
=
Nm
Output speed
n
r
≥ n
L
/ k
E
n
r
=
rpm
Drive power
P
r
≥ M
r
x n
r
/ 9549
p
r
=
kW
Check geared servo motor and determine from the selection table
Check
Selection
Unit
Drive power
P
1
≥ P
r
p
1
=
kW
Output torque
M
2
≥ M
L
M
2
=
Nm
Output speed
n
2,th
≥ n
L
n
2,th
=
rpm
Load capacity of the geared motor
c ≥ k
c ≥ k
I
c =
Short-time maximum torque
no alternating load
M
2,max
≥ M
L,max
M
2,max
=
Nm
at alternating load
M
2,max
x 1.5 ≥ M
L,max
M
2,max
=
Nm
Ratio
i =
Geared motor
g500-....
Order data
Ratio i
Geared motor
Example
3.267
g500-H140
m850-S120/S3960
Example
3.661
g500-S130
m850-S120/S3960
Example
4.889
g500-B240
m850-S120/S3960
Information on project planning