Connection according to EN
The following data is valid for a three-phase mains connection with 400 V.
Mains connection with QUICKON connector
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Connection
X3
Laying system
B2
Connection type
QUICKON connector
Cable type
Flexible
Cable cross-section
Typ.
mm
2
1.5
2.5
Min.
mm
2
1.5
1.5
Max.
mm
2
2.5
2.5
Mains connection M15 connector
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Connection
X3
Laying system
B2
Connection type
M15 connector
Cable type
Flexible
Cable cross-section
Typ.
mm
2
1.5
2.5
Min.
mm
2
1.5
1.5
Max.
mm
2
2.5
2.5
Mains connection cable L1, L2, L3, PE
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Connection
X3
Installation method
B2
Connection type
Cable
Cable type
rigid/flexible
Cable cross-section
Typ.
mm
2
1.0
1.5
Min.
mm
2
0.75
0.75
Max.
mm
2
1.5
1.5
Stripping length
mm
10
10
Information on electrical installation
Connection according to EN
34