Standards and operating conditions
Conformities and approvals
Conformities
CE
2011/65/EU
RoHS Directive
2014/35/EU
Low-Voltage Directive
2014/30/EU
EMC Directive (reference: CE-typical drive system)
EAC
TP TR 004/2011
Eurasian conformity: Safety of low voltage equipment
TP TC 020/2011
Eurasian conformity: Electromagnetic compatibility of technical means
Approvals
CEL
CEL 038-2020
Energy efficiency for China. Affected motors receive a separate label.
cULus
-
UL 1004-1
for USA and Canada (requirements of the CSA
22.2 No. 274)
UL 1004-6
UkrSepro
for Ukraine
Protection of persons and device protection
Degree of protection
EN
EN 60529,EN
60034-5
IP54
Information applies to the mounted and ready-
for-use state
IP65
Temperature class
Insulation system
EN 60034-1
F (155 °C)
Insulation system
Permissible voltage
Limit curve A of the
pulse voltage
IEC/TS
60034-25:2007
IEC/TS 60034-25:2007
IVIC C
IEC 60034-18-41
at 500 V
EMC data
Noise emission
Fulfills requirements
according to
EN 60034-1
A final overall assessment of the drive system is indispensable
Noise immunity
Fulfills requirements
according to
EN 60034-1
A final overall assessment of the drive system is indispensable
Environmental conditions
Climate
Storage
EN IEC
60721-3-1:1997
1K3 (-20 ... +40 °C)
>3 months
1K3 (-20 ... +60 °C)
<3 months
Transport
EN IEC
60721-3-2:1997
2K3 (-20 ... +70 °C)
Operation
EN IEC
60721-3-3:1995 +
A2:1997
3K3 (-10 ... +40 °C)
Operation, without brake
3K3 (-15 ...+40 °C)
Operation without brake, forced ventilated
3K3 (-20 ...+40 °C)
Operation without brake, self-ventilated
Site altitude
0 … 1000 m amsl
-
without current derating
1000 ... 2000 m. amsl
Reduce rated output current by 5 %/1000 m
Air humidity
Without
condensation
-
Average relative humidity 85 %
Technical data
Standards and operating conditions
Conformities and approvals
40