Terminal box, SinCos absolute value encoder with Hiperface
Contact
Name
Meaning
B1
+ UB
B2
GND
Mass
B3
A
Track A / + COS
B4
A¯
Track A inverse /-COS
B5
B
Track B /+SIN
B6
B¯
Track B inverse/-SIN
B7
Z
Zero track /+RS485
B8
Z¯
Zero track inverse /-RS485
B10
Incremental encoder shield
Terminal box, SinCos absolute value encoder with EnDat
Contact
Name
Meaning
B1
+ UB
B2
GND
Mass
B3
A
Track A / + COS
B4
A-
Track A inverse /-COS
B5
B
Track B /+SIN
B6
B-
Track B inverse/-SIN
B7
Daten
EnDat interface data
B8
Daten-
Data inverse EnDat interface
B20
Takt
EnDat interface cycle
B21
Takt-
Inverse EnDat interface cycle
B22
Up Sensor
Up Sensor
B23
0 V Sensor
0 V sensor
B24
Schirm
Encoder housing shield
B25
Not assigned
Terminal box with temperature monitoring R
Contact
Name
Meaning
R1
+
Temperature
R2
-
Temperature sensor -
Electrical installation
Motor connection
Connection via terminal box
33