Parameter
Name / value range / [default setting]
Info
0x1401:005
(PAR 541/005)
RPDO2 communication parameter: Event timer
(RPDO2 config.: Event timer)
0 ... [100] ... 65535 ms
RPDO2: time-out for the monitoring of data reception.
0x1402:001
(PAR 542/001)
RPDO3 communication parameter: COB-ID
(RPDO3 config.: COB-ID)
0x00000000 ... [0x80000400] ... 0xFFFFFFFF
RPDO3: identifier
How to change the identifier:
1
.
Set PDO to "invalid": Set bit 31 to "1".
2
.
Change identifier.
3
.
Reset PDO to "valid": Set bit 31 to "0".
0x1402:002
(PAR 542/002)
RPDO3 communication parameter: Transmission type
(RPDO3 config.: Transm. type)
0 ... [255] ... 255
RPDO3: transmission type in compliance with DS301 V4.02
0x1402:005
(PAR 542/005)
RPDO3 communication parameter: Event timer
(RPDO3 config.: Event timer)
0 ... [100] ... 65535 ms
RPDO3: time-out for the monitoring of data reception.
0x1800:000
TPDO1 communication parameter: Highest subindex
•
Read only
The value "5" is permanently set.
0x1800:001
(PAR 550/001)
TPDO1 communication parameter: COB-ID
(TPDO1 config.: COB-ID)
0x00000001 ... [0x40000180] ... 0xFFFFFFFF
TPDO1: identifier
How to change the identifier:
1
.
Set PDO to "invalid": Set bit 31 to "1".
2
.
Change identifier.
3
.
Reset PDO to "valid": Set bit 31 to "0".
0x1800:002
(PAR 550/002)
TPDO1 communication parameter: Transmission type
(TPDO1 config.: Transm. type)
0 ... [255] ... 255
TPDO1: transmission type in compliance with DS301 V4.02
0x1800:003
(PAR 550/003)
TPDO1 communication parameter: Inhibit time
(TPDO1 config.: Inhibit time)
0.0 ... [0.0] ... 6553.5 ms
TPDO1: minimum time between the transmission of two identical PDOs
(see DS301 V4.02).
0x1800:005
(PAR 550/005)
TPDO1 communication parameter: Event timer
(TPDO1 config.: Event timer)
0 ... [20] ... 65535 ms
TPDO1: cycle time for PDO transmission with transmission type "254".
0x1801:000
TPDO2 communication parameter: Highest subindex
•
Read only
The value "5" is permanently set.
0x1801:001
(PAR 551/001)
TPDO2 communication parameter: COB-ID
(TPDO2 config.: COB-ID)
0x00000001 ... [0xC0000280] ... 0xFFFFFFFF
TPDO2: identifier
How to change the identifier:
1
.
Set PDO to "invalid": Set bit 31 to "1".
2
.
Change identifier.
3
.
Reset PDO to "valid": Set bit 31 to "0".
0x1801:002
(PAR 551/002)
TPDO2 communication parameter: Transmission type
(TPDO2 config.: Transm. type)
0 ... [255] ... 255
TPDO2: transmission type in compliance with DS301 V4.02
0x1801:003
(PAR 551/003)
TPDO2 communication parameter: Inhibit time
(TPDO2 config.: Inhibit time)
0.0 ... [0.0] ... 6553.5 ms
TPDO2: minimum time between the transmission of two identical PDOs
(see DS301 V4.02).
0x1801:005
(PAR 551/005)
TPDO2 communication parameter: Event timer
(TPDO2 config.: Event timer)
0 ... [0] ... 65535 ms
TPDO2: cycle time for PDO transmission with transmission type "254".
0x1802:000
TPDO3 communication parameter: Highest subindex
•
Read only
The value "5" is permanently set.
0x1802:001
(PAR 552/001)
TPDO3 communication parameter: COB-ID
(TPDO3 config.: COB-ID)
0x00000001 ... [0xC0000380] ... 0xFFFFFFFF
TPDO3: identifier
How to change the identifier:
1
.
Set PDO to "invalid": Set bit 31 to "1".
2
.
Change identifier.
3
.
Reset PDO to "valid": Set bit 31 to "0".
0x1802:002
(PAR 552/002)
TPDO3 communication parameter: Transmission type
(TPDO3 config.: Transm. type)
0 ... [255] ... 255
TPDO3: transmission type in compliance with DS301 V4.02
0x1802:003
(PAR 552/003)
TPDO3 communication parameter: Inhibit time
(TPDO3 config.: Inhibit time)
0.0 ... [0.0] ... 6553.5 ms
TPDO3: minimum time between the transmission of two identical PDOs
(see DS301 V4.02).
Configuring the network
CANopen
CANopen process data objects
119