background image

Lenze Americas • 630 Douglas Street • Uxbridge, MA 01569 • USA

Sales (800) 217-9100 • Service (508) 278-9100 • www.lenzeamericas.com

KF01G

13360081

2. 

SCF REMOTE KEYPAD TEMPLATE

  

NOTE: Verify dimensions on printed page before using as a template.

Hold  this  page  against  the  panel  where  the  remote  keypad  is  to  be 
mounted, and use a center punch to mark the location of the three holes.  
The dotted line is the outline of the remote keypad.

4. 

WIRING CONNECTIONS

WARNING!
Improper wiring may result in damage to the Remote Keypad.  Keep 
the remote keypad cable away from power wiring.
The Belden and Carol cables specified consist of two twisted pairs.  Make 
sure one twisted pair is used for power and the other is used for serial 
communications.  Do not mix connections between twisted pairs

Note 1:
The  supplied  cable  can  be  used  for  distances  up  to  8  feet  in  low-
noise  environments.    For  distances  up  to  100  feet,  or  in  high-noise 
environments, use Belden 9842, Carol C4842, or equivalent (24 gauge 
minimum) wire only.

SCF SERIES REMOTE KEYPAD INSTRUCTIONS

(Manual Number:  KF01G)

The SCF Series Remote Keypad option (844-200) allows the SCF Series 
drive to be programmed and controlled from up to one hundred feet away.  
When properly mounted, the remote keypad is rated NEMA 4X.

In addition to the functions available on the front of the SCF drive, the 
remote keypad has Start/Stop and Forward/Reverse functions.

WARNING!
If OEM mode is selected (using Parameter 48), and if the OEM Default 
setting  for  Parameter  14  and/or  15  is  “01”,  the  remote  keypad  will 
be disabled, and the 

STOP key WILL NOT work.  Refer to the SCF 

Installation  and  Operation  Manual  for  information  on  OEM  Default 
settings.

1. 

PARTS LIST

The SCF Remote Keypad kit includes the following parts: 
  (1)  Remote Keypad 

(1)  Gasket 

  (2)  Self-tapping Mounting Screws 

(1)  Instruction Sheet 

  (1)  Eight foot cable

Note:
The supplied cable can only be used for distances up to 8 feet in low-
noise  environments.    For  distances  up  to  100  feet,  or  in  high-noise 
environments, use Belden 9842, Carol C4842, or equivalent (24 gauge 
minimum) wire only.

REMOTE KEYPAD 

(BACK VIEW)

JUMPER

(See NOTE 2

in Section 5)

TXA
TXB
11
2

UP

TXA TXB

1

11

2

2

Cable included with kit 
does not have a shield

SCF TERMINAL STRIP

1/8” hole

1/8” hole

1.57”

1.32”

1.38” to 1.5” hole

3.38”

2.19”

UP

Max Depth = 0.72”

PANEL

REMOTE 
KEYPAD

GASKET

MOUNTING 
SCREWS

3. 

MOUNTING THE REMOTE KEYPAD

The diagram below illustrates how to mount the remote keypad to a panel.  
Use the template in Section 2 to mark the location of the mounting holes 
on the panel.

Note 2:
TB-11  can  supply  up  to  50  mA  of 
power,  and  the  remote  keypad 
requires  40  mA.    To  drive  auxiliary 
relays  using  the  open-collector 
outputs,  an  external  power  supply 
is required.