Communication object list
Bit assignment of command word / status word / error word
10
175
SW-HB 13.0002-EN EN 3.0
Error word (low) (errh_err_field_0)
Bit
Meaning
31
—
30
Limit switch error
29
—
28
Following error monitoring
27
Power stage temperature 5
°
C below maximum
26
Motor temperature 5
°
C below maximum
25
I
@
T with 80%
24 ... 20
—
19
I
@
t-error controller (I
@
t with 100%)
18
I
@
t-error motor (I
@
t with 100%)
17
—
16
SINCOS track signal error
15
DC bus overvoltage
14
DC bus undervoltage
13
DC bus / power stage overcurrent
12
Offset current measurement error
11
—
10
24V-supply error (out of range)
9
12V-electronic supply error
8
5V-electronic supply error
7
Resolver track signal error / carrier failure
6
SINCOS track signal error
5
SINCOS-RS485 communication error
4
SINCOS supply error
3
Insufficient temperature/overtemperature of power electronics
2
Motor overtemperature
1 ... 0
—