Commissioning
Positioning mode
Setting digital outputs
5
72
SW-HB 13.0002-EN EN 3.0
Input
Function
Description
DIN9
Controller enable
With a rising edge, the controller will be initialised and enabled together
with the power stage. With a falling edge, the motor will be decelerated to
speed = 0 and the power stage will be switched off.
Error
acknowledgement
If the controller indicates an error, the falling edge will be used to
acknowledge active errors. If the error acknowledgement has been
successful, the controller will change to ”Ready for operation” and can be
enabled again with the next edge.
Limit switch
acknowledgement
If the motor has reached a limit switch, the falling edge will be used to
allow traversing in the same direction.
DIN8
Positive limit switch Positive (DIN8) and negative (DIN7) setpoints will only be enabled, if the
limit switch inputs are connected with + 24 V (limit switches with NC
contact).
If no signal is received, the drive will decelerate to speed = 0 when the
current limit is reached, the power stage will remain on.
DIN7
Negative limit switch
DIN6
Positioning start
With a rising edge, positioning will be executed with the selected
parameter set.
DIN5
Selection of
positioning
parameter set
Selection of the positioning parameter group
(accelerations / times, positioning speed, subgroup selection with 16 target
positions)
DIN4
DIN3
DIN2
DIN1
DIN0
5.4.10
Setting digital outputs
In positioning mode, you can inform the higher-level control via digital outputs that a
positioning process has been completed/is being completed.
The digital outputs can transfer the following information:
ƒ
Target reached.
ƒ
Remaining path to end of positioning process reached.
ƒ
Homing completed.
Please see the chapter ”Digital outputs” for the configuration of the digital outputs.
(
107)