PROFINET: Invalid module configuration [0x00c86430]
PROFINET: Invalid READ.request during parameter access [0x00c86501]
PROFINET: Invalid WRITE.request during parameter access [0x00c86502]
PROFINET: Data output status bad [0x00c86503]
PROFINET: Invalid station name [0x00c86532]
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
A module or submodule does not comply with the
configuration of the Siemens »STEP7« project.
Check/correct configuration.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
• During the parameter access to data set 47, the
controller has sent an invalid READ.request.
• When reading back the data, the IO Controller has
requested a data length (number of data bytes) that is
to small.
Check/correct configuration.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
• During the parameter access to data set 47, the
controller has sent an invalid WRITE.request.
• When reading back the data, the IO Controller has
requested a data length (number of data bytes) that is
to small.
Check/correct configuration.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Output data invalid.
Connection to the Siemens Controller has been
interrupted.
• Check cables and terminals.
• Plug in the network cable on the PROFINET terminal
X241/X242.
Response
(Lenze setting printed in bold)
Setting:
not possible
None
System fault
Fault
Trouble
Quick stop by trouble
Warning locked
Warning
Information
Cause
Remedy
Station name is not PROFINET-compliant.
Use a PROFINET-compliant station name.