LD5208 U
SER
M
ANUAL
, R
EV
. 0: N
OVEMBER
2005
14
9. TURNING THE INDICATOR ON
1. After all connections have been made, plug in the power cord.
2. Empty the scale
3. Press the ON/OFF key on the front panel to turn the indicator ON.
4. When the LD5208 is powered up a self test routine is initiated during which the following data
is displayed:
Program Number
The software identification code is displayed briefly
e.g. LD5208
Program Date
The date of issue of the software version is displayed briefly
e.g. 290705 (day - month - year)
Display segment test.
All display segments are turned on then off for 2 sec (
8.8.8.8.8.8
)
5. The display shows the weight on the platform, then ZERO.
If the weight is within the zeroing range specified during the configuration of the scale (+2%
or +10% of scale capacity) it will be zeroed automatically.
If the scale can not be zeroed Err 15 is displayed. Unload the scale and press
)
key
momentarily to acknowledge the error.
6. Power up the printer if one is connected to the LD5208.
7. The unit is ready for operation.
....
If any other error message is displayed refer to List of Error codes, chapter 13.
Refer to paragraph 8.3 for description of operation of keys and paragraph 9.2 for description of
functions.