- 3 -

 

 

Before connecting the communication interface signal cable, turn off the UPS  and disconnect  

 

 

the UPS from AC power source.

 

 

DO NOT

 clean the UPS with benzene, thinner or any solvent, use only soft cloth to clean the UPS 

 

 

after it has been turned off.

 

 

Turn on the UPS before turn on all connected loads to prevent surge damage.

 

 

During a heavy rain storm, avoid using electrical appliances including the UPS to prevent 

 

 

damage from lightning strike.

1.4 Battery Safety

  

Warning:  

Even the UPS is disconnected from AC power source, the UPS OUTPUT outlets  

 

 

 

 

 

 

may have hazardous voltage because of battery may continue supply power.

 

 

Warning:  

DO NOT

 dispose of battery in a fire. They may be exploded.

 

 

Caution:  

DO NOT

 disassemble battery. They contains poisonous electrolyte which is  

 

     harmful 

to 

your 

skin 

and 

eyes.

 

 

Caution:   

For battery replacement, replace battery with the same type and rating as 

     originally 

installed 

battery.

 

 

Caution:  

The UPS contains sealed lead acid battery and must be recycled properly. For  

 

 

 

 

 

 

recycling, please return it to ypur local distributor or service center or contact 

 

 

 

 

 

your local recycling center for proper disposal information.

 

 

Caution:  

When the UPS has not been used for a long period of time or UPS is stored for an    

 

 

 

 

 

extended period of time, battery should be fully recharged every three months 

 

 

 

 

 

by plugging the UPS with the AC power source. Then, turn on the UPS and let

 

 

 

 

 

the UPS charge battery for 6 hours.

 

 

When replacing a battery, use tools with insulated handles and remove any watch, rings or 

 

 

other metal objects that you wear in order to avoid electric shock.

- 4 -

INTRODUCTION

2.1 General

    BLUE series is an uninterruptible power supply for office automation equipment (computers 

and peripherals such as monitors, modem, printers, fax machines, etc). Its major function is to 

eliminate any power problems such as a blackout, brown out, sag, surge, spike, etc. that might 

cause malfunctions of the connected loads. It also provide automatic voltage regulator (AVR), surge 

suppressor and backup power system. 

    The BLUE series UPS can be started when there is no utility power to supply power the connected 

loads in an emergency. It display the electrical status and operating status on LCD display and on 

computer's monitor via UPS monitoring software. 

FRONT AND REAR PANEL

3.1 Front panel

Summary of Contents for BLUE-800

Page 1: ...on for installation and operation 2 1 4 Battery safety 3 2 INTRODUCTION 4 3 FRONT AND REAR PANEL 4 3 1 Front panel 4 3 2 Rear panel 6 4 INSTALLATION 7 4 1 Preparation 7 4 2 Installation and operation...

Page 2: ...lets terminal blocks and power source to make sure that they are in good condition To reduce risk from electric shock if you cannot find the electrical ground of the building unplug UPS from AC power...

Page 3: ...utor or service center or contact your local recycling center for proper disposal information Caution When the UPS has not been used for a long period of time or UPS is stored for an extended period o...

Page 4: ...Alarm beep sound every 1 seconds Battery backup power is running out Show Alarm long beep sound UPS malfunction 6 3 2 Rear panel 3 2 1 USB port The communication port for connecting the UPS to comput...

Page 5: ...D screen is lit and shows the input voltage and battery level 8 OPERATION 5 1 Turn on and turn off the UPS 5 1 1 Turn on the UPS by pressing the button at the front panel The LCD screen is lit and sho...

Page 6: ...0 TROUBLESHOOTING Symptoms Possible causes Solutions Blackout occured but UPS does not supply backup pow er Battery power is running out Once the utility line turns back to normal turn on the UPS at l...