background image

- 9 -

 

5.5.1 

Lay down the UPS on the flat surface and unscrew 4 fasteners from the battery cover plate 

 

 

 

as shown in below figure. Then, remove the battery cover plate.

 

5.5.2  

Tilt the UPS and gently pull the battery out of the UPS. Then, disconnect black and red wires 

 

 

 

from the battery terminal respectively.

 

 

 

 

Caution: While disconnecting the battery wires, beware the battery wires end are not 

 

 

 

 

 

    touching  each other to prevent the UPS damage.

 

5.5.3 

Replace new battery by reconnect the black ( - ) and red ( + ) wire to the battery terminals   

   respectively.

 

 

 

 

Caution:  Replace battery with the same number and type as originally installed battery.

 

5.5.4 

Replace and screw the battery cover in place and continue using the UPS normally.

- 10 -

TROUBLESHOOTING

Symptoms

Possible causes

Solutions

Blackout occured, but UPS 
does not supply backup pow-
er.

Battery power is running out.

Once the utility line turns back to 
normal, turn on the UPS at least 6 
hours to recharge battery.

Battery is deteriorating.

Turn on the UPS for at least 6 hours 
to recharge its battery, then test. if 
the symptom persists, it need to re-
place the new battery. Please con-
tact service personnel.

Utility line is normal, but the 
LCD shows 

 blinks with 

alarm beep sound every 0.5 
seconds 

UPS is overloaded.

Reduce loads to 75-89% to keep the 
remaining power for instantaneous 
power consumption of some loads.

Utility line is normal, but UPS 
is supplying backup power 
and the LCD shows 

 

binks.

There is no power supply to 
AC input power cord or the 
AC INPUT power cord is not 
properly plugged in to the 
wall outlet. 

Verify the wall outlet and properly 
plug in the AC INPUT power courd.

Summary of Contents for BLUE-800

Page 1: ...on for installation and operation 2 1 4 Battery safety 3 2 INTRODUCTION 4 3 FRONT AND REAR PANEL 4 3 1 Front panel 4 3 2 Rear panel 6 4 INSTALLATION 7 4 1 Preparation 7 4 2 Installation and operation...

Page 2: ...lets terminal blocks and power source to make sure that they are in good condition To reduce risk from electric shock if you cannot find the electrical ground of the building unplug UPS from AC power...

Page 3: ...utor or service center or contact your local recycling center for proper disposal information Caution When the UPS has not been used for a long period of time or UPS is stored for an extended period o...

Page 4: ...Alarm beep sound every 1 seconds Battery backup power is running out Show Alarm long beep sound UPS malfunction 6 3 2 Rear panel 3 2 1 USB port The communication port for connecting the UPS to comput...

Page 5: ...D screen is lit and shows the input voltage and battery level 8 OPERATION 5 1 Turn on and turn off the UPS 5 1 1 Turn on the UPS by pressing the button at the front panel The LCD screen is lit and sho...

Page 6: ...0 TROUBLESHOOTING Symptoms Possible causes Solutions Blackout occured but UPS does not supply backup pow er Battery power is running out Once the utility line turns back to normal turn on the UPS at l...

Page 7: ...PUT OUTLET Number of backup outlet 3 Number of surge protection outlet not backup 1 FEATURE AC DC start yes Communication interface USB port Monitoring and management software yes Surge protection for...

Reviews: