2.3 Features

Advanced LEONICS Microprocessor control: 

 A specially programmed

microprocessor produced only for LEONICS is used as  the CPU for the UPS.

This makes the ULTRA Series UPS perform faster and more accurately to

protect valuable equipment and its peripherals and provides advanced

control features.

Power Watcher: 

 Full time load power monitoring and battery charge

warnings are provided to make sure that your UPS will be able to properly

backup power to the PC protected by UPS.  "Power Watcher" helps users

know in real time that they are not overloading their UPS. With this useful

feature you can increase loads as much as you want until the UPS  overload

warning is shown.  (LEONICS suggests that for highest  reliability and safety

that you should connect loads at no more than 75 % of rated UPS power.

This allows for loads that change power level during use and provides for

some reserve backup power for some loads.)

Battery Watcher (Battery Replacement Indicator): 

 Every time ULTRA

Series UPS performs a self-test and when the battery has been fully

charged, it will perform a battery condition evaluation to determine

whether the battery used by the ULTRA Series UPS is still good or should

be replaced.  The battery replacement indicator will show when the

battery should be replaced.

Ultra Fast Charger: 

 This UPS features an advanced, 3 stage charger (Bulk -

Boost - Float) to shorten charging time without harming the battery.

Besides fast charging, UPS also maintains the proper charging voltage to

preserve the battery from self-discharge and to make sure that it is always

fully charged and ready to provide backup power to your PC.

Intelligent Battery Management (IBM):  

The intelligent battery

management system will manage charging and discharging to get

longer backup times and prolong battery life.

Advanced Load Outlet Management (ALOM): 

  This feature allows the

user to preset operation of the "Intelligent Channel" via Easy-Mon X

Software.  The user can preset the intelligent output channel to cut  off

power to low priority loads when the UPS is overloaded, over temperature

or has a low battery (available on 1050 VA or higher model only).

- 8 -

Hot Swappable Battery: 

  The user can replace the battery even when the

UPS is running and without turning off the computer as long as mains

power is available.

Surge Protection for Telephone Line: 

  Surge protection protects

equipment data from surges that come from telephone line (RJ11).

Surge Protection for LAN Line (option): 

  Surge protection protects

equipment data from surges that come from LAN line.  These special

sockets can accept either telephone plugs (RJ11) or LAN plugs (RJ45).

Perfect LED Display (depend on model): 

 Attractive outlook with full

function LED display.  It shows load level, input voltage level, battery level,

battery replacement condition and overload condition.

Perfect LCD Display (depend on model): 

 Attractive outlook with full

function LCD  display.  It shows load level, input voltage level, battery level,

battery replacement condition and overload condition.

Easy Display (depend on model): 

 Simple outlook with easy function

display.  It shows utility line status, battery status and load status.

Multi-function switch :  

Single switch with 4 functions, very convenient to users :

1. Turn on / Turn off UPS

2. Mute audible alarm

3. Self-test switch

4. Switch display mode (For the UPS with LED display only.)

Extend Backup Time (option): 

 It extends the battery unit to increase the

duration of UPS  backup time. It can protect data with extra effectiveness.

Inverter temperature sensor (option): 

 When the UPS is operating under backup

mode, the inverter temperature sensor will check the temperature inside inverter and

warning when the temperature is too high.  You should reduce the  load immediately.

Automatic voltage regulator -37% to +30%. buck and double boost (option) :

With it’s especially wide range automatic input voltage regulator,  from –37% to +30%,

UPS can lessen backup mode transferred transaction, which helps you save the

battery‘s energy for emergencies, it also prolongs your battery life.  (This optional is

special for specific models, please see your features on the side of the carton).

- 9 -

Summary of Contents for Ulta Series

Page 1: ......

Page 2: ...nd quick reference for our service please fill the requested information in the blanks below UPS Model __________________________________ Serial Number __________________________________ Purchased dat...

Page 3: ...including UPS to prevent it from lightning 1 2 11Use soft cloth to clean the UPS when it is turned OFF DO NOT clean it with solvent 1 2 12DO NOT use the UPS with life recovery instruments The failure...

Page 4: ...ced Load Outlet Management ALOM which the user can program to turn off a low priority outlet when there is a low battery or overload condition for 1050VA or higher only For the UPS with LED display an...

Page 5: ...e Power Watcher provides information about load conditions whether or not you are overloading your ULTRA Series UPS PowerWatcher is continuously monitoring in real time both for the stabilizer and inv...

Page 6: ...et the intelligent output channel to cut off power to low priority loads when the UPS is overloaded over temperature or has a low battery available on 1050 VA or higher model only 8 Hot Swappable Batt...

Page 7: ...y power status Lit UPS is operating under its normal mode Blink UPS is operating in the backup mode Note 1 For the UPS with inverter temperature sensor option It will be blink fastly when the temperat...

Page 8: ...inks only at a time Please refer to section 6 3 The meaning of LCD display 3 1 7 Battery Level Shows the battery voltage from low to high level 3 1 7 1 For the UPS with LED display Lamp no 4 11 green...

Page 9: ...3 2 5 2 Intelligent Channel A supplemental outlets that the user can manage and control by Easy Mon X Software See item 12 2 The Intelligent Channel can be set to permanently turn on or can be set to...

Page 10: ...h enable disable ULTRA Series UPS 650VA or smaller ULTRA Series UPS 1050VA or higher Set the dip switch SW1 to ON as shown if you want the UPS to shutdown automatically in backup mode when the load is...

Page 11: ...wer cord to the electrical outlet Press the multi function switch for 0 5 second then release All indicator lights will blink after that UPS will start up the self test See details in section 5 3 1 Wh...

Page 12: ...de provided on the accompanying CD ROM 5 3 4 Auto test every 2 weeks If there is no manual or scheduled self test during the past 2 weeks the UPS will do a self test automatically You can also set the...

Page 13: ...e lit when load are between 51 to 75 Lamp no 4 5 6 and 7 are lit when loads are between 76 to100 Lamp no 4 5 and 6 are lit and lamp no 7 is blink when loads are over 100 and you should reduce the load...

Page 14: ...The lamp no 9 is lit when self test is cancelled because of battery power is too low The lamp no 11 is lit when it need to replace the battery 24 25 6 3 The meaning of LCD display 6 3 1 Input Voltage...

Page 15: ...en a stabilizer fault The second indicator is lit when a charger fault 27 The third indicator is lit when software failure The forth indicator is lit when CPU error The fifth indicator is lit when an...

Page 16: ...the load when it first starts Do nothing normal operation Turn off loads and wait until the AC source returns to normal Then turn on loads again or Usebackuppowerfrom UPS until battery low alarm alert...

Page 17: ...or 31 When the UPS warns you to replace the battery see details in item 6 2 3 2 and 6 3 4 2 Warning You can replace UPS s battery while it is operating But for your safety we recommends that you turn...

Page 18: ...reconnect each wires connection to each battery same as before Put the battery strip back in its position 9 6 Re screw the battery strip with the case 9 7 Replace and screw the front panel in place a...

Page 19: ...Driver to read the instructions for installing USB driver 12 5 Follow the instruction on screen to install UPS driver 12 6 When installation is completed restart computer 12 7 Install Easy Mon X Packa...

Reviews: