background image

 

 

 

 

LEONTON

 

BG5-1204-SFP-24 Series

 

(BG5-1204-SFP-24 / BG5-1204-SFP-24-T)

 

 

 
 

 

 
 
 
 

User Manual

 

 

 

 

Summary of Contents for BG5-1204-SFP-24 Series

Page 1: ...LEONTON BG5 1204 SFP 24 Series BG5 1204 SFP 24 BG5 1204 SFP 24 T User Manual ...

Page 2: ...ut not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Leonton Technologies Co Ltd will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are period...

Page 3: ...his device could void the user s authority to operate the equipment Déclaration FCC Cet équipement a été testé et reconnu conforme aux limites de la classe A pour les équipements numériques conformément à la section 15 des Réglementations FCC Ces limites sont conçues pour fournir une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel Cet équipement génère utili...

Page 4: ...equired to take adequate measures CE Mark Avertissement Ceci est un produit de classe A Dans un environnement domestique ce produit peut être utilisé en présence d interférences radio This document is the current official release manual Please check our website www leonton com for any updated manual or contact us by e mail sales leonton com ...

Page 5: ...p View 4 LED Indicators 5 PoE Port LED Indicators 7 PoE Dip Switch 9 Relay Contact Alarm Warning 9 Ethernet Ports 10 Cabling 11 Wiring the Power Inputs 13 Wiring the Fault Alarm Contact 14 Grounding Note 14 Mounting Installation 15 DIN Rail Mounting 15 Wall Mounting 17 Hardware Installation 18 Installation Steps 18 Trouble Shooting 20 ...

Page 6: ...10 to 65 C and another with a wide operating temperature of 40 to 75 C this series is designed to meet any needs for industrial automation outdoor application and harsh environments Key Features Interface Performance All Copper ports support auto MDI MDI X function Embedded 8 10 100 1000Basw T X with 4 bt PoE PSE 90W Port 4 at PoE PSE 30W Port and 4 100 1000Base F X SFP Slots Store and forward swi...

Page 7: ...ser un dispositif de protection sur l entrée d alimentation Fourniture par courant industriel homologué UL Les spécifications matérielles les ports les informations de câblage et l installation du câblage du convertisseur de média industriel seront décrits dans ce manuel d utilisation Warning Labels The caution label means that you should check the certain information on user manual when working w...

Page 8: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of BG5 1204 SFP 24 series W x H x D is 54mm x 142mm x 99mm Figure 2 1 Physical Dimensions ...

Page 9: ...the BG5 1204 SFP 24 series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 55VDC Figure 2 3 Top Panel View LED Indicator Console Port USB Port Reset Button PoE Status LED 10 100 1000Mbps Link Act LED 10 100 1000Tx RJ45 at PoE Copper Port 5 8 Port 100 1000 SFP Port 100 1000 SFP Port Link Act LED PoE DIP Switch 10 100 1000Tx RJ45 bt PoE Copper Port...

Page 10: ...oftware setting MASTER Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active RING Green On ERPS Ring Network is active and works well Flashing ERPS Ring works abnormally or misconfigure Off ERPS Ring Network is not active PoE Load max 240w Off PoE Load 50 Blue On PoE Load 51 70 Red On PoE Load 71 90 Red Flashing PoE Load 91 100 GE Port 1 8 Copper Upper LED Green On Connec...

Page 11: ...g Flashing The port is trying to recover from event failure Frequency 20secs time at PoE Mode Port 5 8 Copper Lower LED Amber On Supplying PoE at 30w af power to the powered device Off Not connected to a Powered Device Green Amber Alternating Flashing The port is trying to recover from event failure Frequency 20secs time SFP Link Active Port 9 12 Green On Connected to network 1Gbps Flashing Networ...

Page 12: ...iority PoE port will be shutdown The PoE LED of the port will act cyclically as below until the port is recovered from the event After the PoE port is recovered from the PoE budget overload event the PoE LED of the will act cyclically as below until the event indicator is clear manually AF AT Amber BT Green PoE Port Over Current Event Per Port When the current limit of the specific PoE port is exc...

Page 13: ...t the PoE LED of the port will act cyclically as below until the event indicator is clear manually AF AT Amber BT Green Dual PD Fail Event When one channel of the connected dual PD is failed the PoE port will be shutdown The PoE Port LED of the port will act cyclically as below until the port is recovered from the event After the PoE port is recovered from the Dual PD Fail event the PoE LED of the...

Page 14: ...n 1 24VDC 1A resistive normal open on 6 pin terminal block The relay contact alarm will be triggered when anyone of the pre configured events occurs User can configure the event warning for the events listed below Software Default OFF The relay contact alarm will be triggered when anyone of the listed events occurs Key trigger event 1 Power 1 or Power 2 is inactive Key trigger event 2 PoE total lo...

Page 15: ...Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45 Pin Assignments Table 2 3 Crossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 TP0 3 TP1 1 TP0 1 TP1 2 TP0 6 TP1 2 TP0 2 TP1 3 TP1 1 TP0 3...

Page 16: ...hat complies with IEC 60825 1 and classified as Class 1 laser product Attention Veuillez utiliser un émetteur récepteur optique SFP conforme à la norme CEI 60825 1 et classé comme produit laser de classe 1 To connect the transceiver and LC cable please follow below steps Step 1 Insert the SFP transceiver module into the SFP slot as shown below in Figure 2 4 Notice that the triangle mark is at the ...

Page 17: ... shown below Step 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 7 Figure 2 7 Remove LC Connector Step 2 Push down the metal clasp and pull the transceiver out by the plastic part as shown below in Figure 2 8 Figure 2 8 Pull Out from the SFP Module ...

Page 18: ...tor as shown below in Figure 2 9 Figure 2 9 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 10 Figure 2 10 Power Terminal Block Caution Only use copper conductors 125 C tighten to 7 in lbs 0 79 Nm The wire gauge for the terminal block should range between 18 20 AWG Attention Utilisez uniquement des conducteurs en cuivre 125 C...

Page 19: ... to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit être compris entre 12 et 24 AWG Si vous n utilisez qu une seule source d alimentation jumelez les broches 1 à 5 et les broches 2 à 6 pour éliminer l alarme de panne de courant Grounding Note Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run ...

Page 20: ...gure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Ethernet switch Step 2 To remove the DIN Rail bracket do the opposite from Step 1 Step 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of ...

Page 21: ...pull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Ethernet switch from the rail do the opposite from the above steps ...

Page 22: ...ustrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall Step 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail Bracket from the Switch and Install the Wall Mount Bracket B...

Page 23: ...e Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection Step 6 Insert one side of the RJ 45 cable into Switch s Ethernet port and on the other side into the networking device s Ethernet port e g switch PC or server The Ethernet port s RJ 45 LED on the industrial S...

Page 24: ...e intégrant l équipement est de la responsabilité de l assembleur du système Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agit d un module de TYPE OUVERT et doit être installé dans une caractéristique finale d enceinte de sécurité Caution This device is intended for use indoor and at altitudes up to 2000 meters Attention Cet ...

Page 25: ...s which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Leonton for technical support service if the problem still cannot b...