7
Cabling
Use the four twisted-pair, category 5e, or the above cabling for RJ-45 port connections. The cable
between the switch and the link partner (switch, hub, workstation, etc.) must be less than 100
meters (328 ft.) long.
Wiring the Power Inputs
Please follow the below steps to insert the power wire.
Step 1
Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in Figure 2.1.
Figure 2.1: Power Terminal Block
Step 2
Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.2.
Figure 2.2: Power Terminal Block
Note
:
Only use copper conductors,
60/75°C
, tighten to
5 lbs
.
The wire gauge for the terminal block should range between
18~20 AWG
.