background image

11 

 

Mounting  Installation 

DIN-Rail Mounting 

The DIN-Rail is pre-installed on the industrial Ethernet switch from the factory. If the DIN-Rail is 

not on the industrial Ethernet switch, please see Figure 3.1 to learn how to install the DIN-Rail 

on the switch.

 

 

Figure 3.1: The Rear Side of the Switch and DIN-Rail Bracket

 

 

Follow the steps below to learn how to hang the industrial Ethernet switch.

 

Step 1

 

Use the screws to install the DIN-Rail bracket on the rear side of the industrial Ethernet 

switch.

 

Step 2

 

To remove the DIN-Rail bracket, do the opposite from Step 1.

 

Step 3

 

After the DIN-Rail bracket is installed on the rear side of the switch, insert the top of 

the DIN-Rail on to the track as shown below in Figure 3.2.

 

Summary of Contents for EG2-1604-SFP Series

Page 1: ...LEONTON EG2 1604 SFP Series EG2 1604 SFP EG2 1604 SFP T User Manual...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...he grantee of this device could void the user s authority to operate the equipment D claration FCC Cet quipement a t test et reconnu conforme aux limites de la classe A pour les quipements num riques...

Page 4: ...equired to take adequate measures CE Mark Avertissement Ceci est un produit de classe A Dans un environnement domestique ce produit peut tre utilis en pr sence d interf rences radio This document is t...

Page 5: ...hysical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 10 Grounding Note 10 Mounting Installation 11 DIN Rai...

Page 6: ...ng an operating temperature of 10 C 65 C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environmen...

Page 7: ...tion sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du convertisseur de m d...

Page 8: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of EG2 1604 SFP series W x H x D is 59mm x 142mm x 99mm Figure 2 1 Physical Dimensions...

Page 9: ...Panel Top View Figure 2 3 below shows the top panel of the EG2 1604 SFP series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 48VDC Figure 2 3 Top...

Page 10: ...Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional LINK ACT SFP Port Green On Connected to network 1000Mbps Flashing Networking is a...

Page 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45...

Page 12: ...hat complies with IEC 60825 1 and classified as Class 1 laser product Attention Veuillez utiliser un metteur r cepteur optique SFP conforme la norme CEI 60825 1 et class comme produit laser de classe...

Page 13: ...hown below Step 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 7 Figure 2 7 Remove LC Connector Step 2 Push down the metal clasp...

Page 14: ...tor as shown below in Figure 2 9 Figure 2 9 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 10 Figure 2 10 Power Terminal Block...

Page 15: ...n 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit tre compris entre 12 et 24 AWG Si vous n utilisez qu une seule source d alimentation jumele...

Page 16: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Page 17: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Page 18: ...strial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 19: ...Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection Step 6 Ins...

Page 20: ...st me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agi...

Page 21: ...which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user...

Reviews: