background image

 

Fiber Port 

The small form-factor pluggable (SFP) is a compact optical transceiver used in optical communications for 

both telecommunication and data communication applications. 

Please follow the below steps to insert the fiber port.

 

Step 1.

 

Pull out the SFP module which needs to be replaced. 

Step 2.

 

Put the fiber cable through the metal end lock, sealing, and cap. 

Step 3.

 

Insert the SFP transceiver into the Metal Panel Lock and tighten and seal all parts. 

 

 

Caution:

 

Please employ optional optical transceiver (SFP) that complies with IEC 60825-1 and 

classified as Class 1 laser product. 

Attention:

 Veuillez utiliser un émetteur-récepteur optique (SFP) conforme à la norme CEI 60825-1 

et classé comme produit laser de classe 1. 

 

 

Summary of Contents for EG5-1802-M12XB-10GSFP-67

Page 1: ...EG5 1802 M12XB 10GSFP 67 EG5 1802 M12XB 10GSFP T67...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...tions FCC Ces limites sont con ues pour fournir une protection raisonnable contre toutes interf rences nuisibles dans un milieu r sidentiel Cet quipement g n re utilise et peut mettre de l nergie de f...

Page 4: ...Front Panel 4 Bottom View 4 LED Indicators 5 Ethernet Ports 6 Fiber Port 7 USB Port 8 Console Port 8 Power Inputs 9 Relay Contact and Digital Input 10 Grounding Note 12 Bypass Function 12 Reset to De...

Page 5: ...erature of 40 C 70 C this series is designed to meet any needs for industrial automation application and harsh environments Key Features Interface Performance Copper port support auto MDI MDI X functi...

Page 6: ...externe veuillez utiliser un dispositif de protection sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et...

Page 7: ...3 HARDWARE DESCRIPTION Physical Dimensions Figure 2 1 below shows the physical dimensions of EG5 1802 M12XB 10GSFP 67 series W x H x D is 295mm x 160mm x 101 3mm Figure 2 1 Physical Dimensions...

Page 8: ...nsure easier plugging and safer operation The LED indicates various status by different colors and shapes of the light Besides this series supports console USB DI DO and dual DC power inputs 24 55VDC...

Page 9: ...ng Firmware Upgrade Master Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On ERPS Ring Network is active and work well Flashing ERPS Ring works abnormally o...

Page 10: ...BI_DD 6 BI_DD 7 BI_DC 8 BI_DC Table 2 2 Note and signs represent the polarity of the wires that make up each wire pair Connection of Cables Use the twisted pair cable category 5e or the above cabling...

Page 11: ...module which needs to be replaced Step 2 Put the fiber cable through the metal end lock sealing and cap Step 3 Insert the SFP transceiver into the Metal Panel Lock and tighten and seal all parts Caut...

Page 12: ...on backup restore M12 connector M12 4 Pin A Coded female Connector Pinouts Function 1 DN 2 VBUS 3 GND 4 DP Console Port It is a M12 5 Pin A Coded female connector Baud rate 115 200bps 8 N 1 M12 connec...

Page 13: ...assignment M12 5 Pin K Coded Male Connector Pinouts Function 1 V1 2 V1 3 V2 4 V2 5 GND Table 2 3 Connection of Cables Minimum Wire Gauge 18AWG Please follow the below steps to insert the power wire St...

Page 14: ...Power 1 or Power 2 was inactive 3 If any one of all PoE ports exceeds 30Watts for PoE models 4 Event happened by software setting Relay is closed under the conditions below 1 No event after reboot 2...

Page 15: ...tage the DI function will be triggered Table 2 5 is shown a detail specification of the digital input Specification Description Level 0 Low 30 8VDC Will trigger DI function active trigger states Level...

Page 16: ...es loses power Ethernet ports P8 and P16 will bypass the power lost Ethernet switch to prevent the network from disconnecting Take Figure 2 6 for example if Switch B has power failure the bypass funct...

Page 17: ...nded use the M5 screws Step 2 Based on the Figure 3 2 Physical Dimensions which is shown the positions of 4 screw holes on the left and right side of the switch to make 4 screw holes on a wall accordi...

Page 18: ...help on how to wire power please refer to the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 4 Prepare the M12 cable for Ethernet connection Step 5 Inse...

Page 19: ...st me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agi...

Page 20: ...which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user...

Reviews: