background image

LED Indicators 

There  are  LED  light  indicators  located  on  the  front  panel  of  the  industrial  Ethernet  switch  that 
display the power status and network status. Each LED indicator has a different color and has its 
own specific meaning, see below in Table 2.1.

 

LED

 

Color

 

Description

 

P1

 

Green

 

On

 

Power input 1 is active

 

Off

 

Power input 1 is inactive

 

P2

 

Green

 

On

 

Power input 2 is active

 

Off

 

Power input 2 is inactive

 

Fault

 

Red

 

On

 

Power input 1 or 2 is inactive

 

Off

 

Power input 1 and 2 are both functional

 

LAN Port 

LINK/ACT/SPEED

 

Green

 

 

On

 

Connected to network, 1000Mbps

 

Flashing

 

Networking is active

 

Off

 

Not connected to network

 

Green

 

 

On

 

Connected to network, 10/100Mbps

 

Flashing

 

Networking is active

 

Off

 

Not connected to network

 

PoE 1-4

 

Green

 

On

 

The port is supplying power to the powered-device

 

Off

 

No powered-device attached or power supplying fails

 

Table 2.1: LED Indictors for PG2-0500 Series

 

Summary of Contents for PG2-0500 Series

Page 1: ...Leonton PG2 0500 Series PG2 0500 PG2 0500 T User Manual Version 1 0...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Page 4: ...ription 3 Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Mounting Installation 9 DIN Rail Mountin...

Page 5: ...C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environments Key Features Interface Performance A...

Page 6: ...on If the DC voltage is supplied by an external circuit please use a protection device on the power supply input Supply by UL Listed industrial use power The industrial Ethernet switch s hardware spec...

Page 7: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of PG2 0500 series W x H x D is 30mm x 142mm x 99mm Figure 2 1 PG2 0500 Series Physical Dimensions...

Page 8: ...tch is shown below in Figure 2 2 Figure 2 2 The Front Panel of PG2 0500 Series Top View Figure 2 3 below shows the top panel of the PG2 0500 series switch that is equipped with one 6 pin removal termi...

Page 9: ...P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional LAN Port LINK ACT SPEED Green On Connected to...

Page 10: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45...

Page 11: ...insert the power wire Step 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 14 Figure 2 14 Power Termina...

Page 12: ...luding power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 16 Figure 2 16 W...

Page 13: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Page 14: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Page 15: ...ottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket...

Page 16: ...the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power In...

Page 17: ...assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicat...

Reviews: