14 

 

Hardware  Installation 

Installation Steps 

This section will explain how to install PG2-1604-SFP series.

 

 

Installation Steps

 

Step 1.

 

Unpack the industrial Switch from the original packing box.

 

Step 2.

 

Check if the DIN-Rail bracket is screwed on the industrial Switch.

 

 

If the DIN-Rail is not screwed on the industrial Switch, please refer to the 

DIN-Rail Mounting

 

section for DIN-Rail installation.

 

 

If you want to wall mount the industrial Switch, please refer to the 

Wall Mounting

 section for 

wall mounting installation.

 

Step 3.

 

To hang the industrial Switch on a DIN-Rail or wall, please refer to the 

Mounting Installation

 

section.

 

Step 4.

 

Power on the industrial Switch and then the power LED light will turn on.

 

 

If you need help on how to wire power, please refer to the 

Wiring the Power Inputs

 section.

 

 

Please refer to the 

LED Indicators

 section for LED light indication.

 

Step 5.

 

Prepare the twisted-pair, straight-through category 5 cable for Ethernet connection.

 

Step 6.

 

Insert one side of the RJ-45 cable into Switch’s Ethernet port and on the other side into the 

networking device’s Ethernet port, e.g. switch PC or server. The Ethernet port’s (RJ-45) LED 

on the industrial Switch will turn on when the cable is connected to the networking device.

 

 

Please refer to the 

LED Indicators

 section for LED light indication.

 

Step 7.

 

Insert  one  side  of  the  SFP  cable  into  Switch’s  SFP  port  and  on  the  other  side  into  the 

networking  device’s  SFP  port,  e.g.  switch  or  server.  The  SFP  port’s  LED  on  the  industrial 

Switch will turn on when the cable is connected to the networking device.

 

 

Please refer to the 

LED Indicators

 section for LED light indication.

 

Step 8.

 

When all connections are set and the LED lights all show normal, the installation is complete.

 

 

 

Summary of Contents for PG2-1604-SFP Series

Page 1: ...LEONTON PG2 1604 SFP Series PG2 1604 SFP PG2 1604 SFP T User Manual...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...he grantee of this device could void the user s authority to operate the equipment D claration FCC Cet quipement a t test et reconnu conforme aux limites de la classe A pour les quipements num riques...

Page 4: ...equired to take adequate measures CE Mark Avertissement Ceci est un produit de classe A Dans un environnement domestique ce produit peut tre utilis en pr sence d interf rences radio This document is t...

Page 5: ...hysical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 10 Grounding Note 10 Mounting Installation 11 DIN Rai...

Page 6: ...ving an operating temperature of 10 C 65 C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environm...

Page 7: ...tion sur l entr e d alimentation Fourniture par courant industriel homologu UL Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du convertisseur de m d...

Page 8: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of PG2 1604 SFP series W x H x D is 59mm x 142mm x 99mm Figure 2 1 Physical Dimensions...

Page 9: ...op View Figure 2 3 below shows the top panel of the PG2 1604 SFP series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 48 55VDC Figure 2 3 Top Panel V...

Page 10: ...is inactive Off Power input 1 and 2 are both functional LINK ACT SFP Port Green On Connected to network 1000Mbps Flashing Networking is active Off Not connected to network Amber On Connected to netwo...

Page 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45...

Page 12: ...hat complies with IEC 60825 1 and classified as Class 1 laser product Attention Veuillez utiliser un metteur r cepteur optique SFP conforme la norme CEI 60825 1 et class comme produit laser de classe...

Page 13: ...hown below Step 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 7 Figure 2 7 Remove LC Connector Step 2 Push down the metal clasp...

Page 14: ...tor as shown below in Figure 2 9 Figure 2 9 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 10 Figure 2 10 Power Terminal Block...

Page 15: ...n 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit tre compris entre 12 et 24 AWG Si vous n utilisez qu une seule source d alimentation jumele...

Page 16: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Page 17: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Page 18: ...strial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 19: ...Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection Step 6 Ins...

Page 20: ...st me int grant l quipement est de la responsabilit de l assembleur du syst me Caution This is an OPEN TYPE module and should be installed in a final safety enclosure characteristic Attention Il s agi...

Page 21: ...which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user...

Reviews: