background image

Contents

 

 
 

Overview ..................................................................................................................... 1 

Key Features ............................................................................................................ 1 

Package Contents ..................................................................................................... 2 

Safety Precaution ..................................................................................................... 2 

Hardware Description ................................................................................................. 3 

Physical Dimensions ................................................................................................. 3 

Front Panel ............................................................................................................... 4 

Top View .................................................................................................................. 4 

LED Indicators .......................................................................................................... 5 

Ethernet Ports .......................................................................................................... 5 

Cabling ..................................................................................................................... 6 

Wiring the Power Inputs .......................................................................................... 7 

Wiring the Fault Alarm Contact ................................................................................ 8 

Mounting Installation ................................................................................................. 9 

DIN-Rail Mounting .................................................................................................... 9 

Wall Mounting ....................................................................................................... 11 

Hardware Installation ............................................................................................... 12 

Installation Steps .................................................................................................... 12 

Trouble Shooting ...................................................................................................... 13 

 

Summary of Contents for PT2-0501-M-24 Series

Page 1: ...Leonton PT2 0501 M 24 Series PT2 0501 M 24 PT2 0501 M 24 T User Manual Version 1 0 ...

Page 2: ...ut not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Leonton Technologies Co Ltd will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are period...

Page 3: ... the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Ca...

Page 4: ...cription 3 Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 5 Cabling 6 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Mounting Installation 9 DIN Rail Mounting 9 Wall Mounting 11 Hardware Installation 12 Installation Steps 12 Trouble Shooting 13 ...

Page 5: ...ng temperature of 10 C 65 C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environments Key Features Interface Performance All Copper ports support auto MDI MDI X function Embedded 4 10 100Tx PSE 30W Port and 1 100Fx SC ST type connector with Multi Single mode Store and forward switching architect...

Page 6: ...ntion If the DC voltage is supplied by an external circuit please use a protection device on the power supply input Supply by UL Listed industrial use power The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual ...

Page 7: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of PT2 0501 M 24 series W x H x D is 46mm x 142mm x 99mm Figure 2 1 PT2 0501 M 24 Series Physical Dimensions ...

Page 8: ...hown below in Figure 2 2 Figure 2 2 The Front Panel of PT2 0501 M 24 Series Top View Figure 2 3 below shows the top panel of the PT2 0501 M 24 series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 36VDC Figure 2 3 Top Panel View of PT2 0501 M 24 Series ...

Page 9: ... is active Off Not connected to network Green On Connected to network 10Mbps Flashing Networking is active Off Not connected to network PoE Port 1 4 Green On The port is supplying power to the powered device Off No powered device attached or power supplying fails SC ST Port LINK ACT Green On Connected to network 10Mbps Flashing Networking is active Off Not connected to network Table 2 1 LED Indict...

Page 10: ...al Pin Number Signal Pin Number Signal Pin Number Signal 1 TP0 3 TP1 1 TP0 1 TP1 2 TP0 6 TP1 2 TP0 2 TP1 3 TP1 1 TP0 3 TP1 3 TP0 4 TP2 7 TP3 4 TP2 4 TP3 5 TP2 8 TP3 5 TP2 5 TP3 6 TP1 2 TP0 6 TP1 6 TP0 7 TP3 4 TP2 7 TP3 7 TP2 8 TP3 5 TP2 8 TP3 8 TP2 Table 2 3 Note and signs represent the polarity of the wires that make up each wire pair Cabling Use the four twisted pair category 5e or the above cab...

Page 11: ...ontacts on the terminal block connector as shown below in Figure 2 14 Figure 2 14 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 15 Figure 2 15 Power Terminal Block Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG ...

Page 12: ...cluding power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 16 Figure 2 16 Wiring the Fault Alarm Contact Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power faul...

Page 13: ...gure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Ethernet switch Step 2 To remove the DIN Rail bracket do the opposite from Step 1 Step 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of ...

Page 14: ...pull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Ethernet switch from the rail do the opposite from the above steps ...

Page 15: ...bottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall Step 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail Bracket from the Switch Below in Figure 3 5...

Page 16: ... to the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection Step 6 Insert one side of...

Page 17: ...To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the powe...