Digidrive SK Getting Started Guide
41
Issue Number: d
www.leroy-somer.com
Sa
fe
Rat
in
Me
ch
El
Ke
yp
Pa
ra
Q
Com
D
O
P
UL L
Action
Detail
Before power up
Ensure:
•
The drive enable signal is not given, terminal B4 is open
•
The motor is connected to the drive
•
The motor connection is correct for the drive
∆
or Y
•
The correct supply voltage is connected to the drive
Power up the
drive
Ensure:
•
The drive displays:
Enter minimum
and maximum
speeds
Enter:
•
Minimum speed Pr
01
(Hz)
•
Maximum speed Pr
02
(Hz)
Enter
acceleration and
deceleration
rates
Enter:
•
Acceleration rate Pr
03
(s/100Hz)
•
Deceleration rate Pr
04
(s/100Hz)
Set keypad
control
Enter:
•
PAd
into Pr
05
Enter motor
nameplate
details
Enter:
•
Motor rated current in Pr
06
(A)
•
Motor rated speed in Pr
07
(rpm)
•
Motor rated voltage in Pr
08
(V)
•
Motor rated power factor in Pr
09
•
If the motor is not a standard 50/60Hz motor, set Pr
39
accordingly
Ready to autotune
Enable and run
the drive
Close:
•
The enable signal
•
Press the
START key
Autotune
The Digidrive SK will carry out a non-rotating autotune on
the motor.
The motor must be stationary to carry out an autotune
correctly.
The drive will carry out a non-rotating autotune every time it
is first started after each power-up. If this will cause a
problem for the application, set Pr
41
to the required value.
Autotune
complete
When the autotune has been completed, the display will show:
Ready to run
Run
The drive is now ready to run the motor.
Increasing and
decreasing speed
Press the
UP key to increase the speed
Press the
DOWN key to decrease the speed
Stopping
Press the
STOP/RESET key to stop the motor
Pr 02
t
Pr 01
100Hz
Pr 03
t
Pr 04
Mot X XXXXXXXXX
No XXXXXXXXXX kg
IP55 I.cl F C 40 s S1
°
V
Hz min
-1
kW cos
φ
A
230
400
50 1445 2.20 0.80 8.50
4.90
CN = 14.5Nm
240
415
50 1445 2.20 0.76 8.50
4.90
CN = 14.4Nm
CTP- VEN 1PHASE 1=0,46A P=110W R.F 32MN
I.E
.C
3
4
1
(8
7)
cos
∅
σ
L
S
R
S
To implement a Forward/Reverse switch, Set Pr
11
= 2 (when the drive is locked).
NOTE