14
COMMISSIONING
E27 Gearless - Installation and maintenance
5323 en - 2018.04 / c
7 - COMMISSIONING
Check that the electrical equipment is correctly earthed
before starting work.
Before commissioning the machine, check that all the fixings
and electrical connections are correctly tightened.
During commissioning, check for noise and vibration and
monitor the current and voltage on the machine while it is
operating at rated load.
8 - MAINTENANCE
8.1 - Bearings
The bearings do not require any maintenance as they are
greased for life.
8.2 - After one month’s operation
- Check that the screws and electrical connections are
correctly tightened.
- Check that there is no abnormal noise. Check the vibration.
We recommend to stop the lift in case of tangible vibration
and to control the complete installation.
- Check the brakes airgap. Please refer to the appendix 1 of
this manual.
8.3 - After an emergency stop
Check the brakes airgap. Please refer to the appendix 1 of
this manual.
8.4 - Every year
Same as section 8.2.
9 - APPENDIX 1
9.1 - Failsafe brakes
See following pages