Technical specifications
INTORQ | BA 14.0197 | 06/2014
19
3.5
Emissions
Electromagnetic compatibility
If an INTORQ rectifier is used for the DC switching of the spring-applied brake and if the operating frequency
exceeds five switching operations per minute, the use of a mains filter is required.
If the spring-applied brake uses a rectifier of another manufacturer for the switching, it may become neces-
sary to connect a spark suppressor in parallel with the AC voltage. Spark suppressors are available on re-
quest, depending on the coil voltage.
Heat
Since the brake converts kinetic energy as well as mechanical and electrical energy into heat, the surface
temperature varies considerably, depending on the operating conditions and possible heat dissipation. Un-
der unfavourable conditions, the surface temperature can reach 130 °C.
Noise
The switching noise during engagement and disengagement varies depending on the air path, braking
torque and brake size.
Depending on the natural oscillation after installation, operating conditions and the state of the friction sur-
faces, the brake may squeak during braking.
Others
The abrasion of the friction parts produces dust.
NOTICE
The user must ensure compliance with EMC Directive 2004/108/EC using appropriate controls
and switching devices.