Electrical installation
INTORQ | BA 14.0197 | 06/2014
31
5.1.2
Switching suggestions
Fig. 14
INTORQ BFK464 connection diagram
Switching on
❚
K2/K4 must be switched on before or at the same time as K1/K3!
Switching off
❚
Normal - AC switching
- K2/K4 remain closed
- K1/K3 open
❚
Emergency stop - DC switching
- K1/K3 and K2/K4 are opened at the same time
5.2
Bridge/half-wave rectifiers (optional)
BEG-561-
-
The bridge/half-wave rectifiers are used to supply electromagnetic DC spring-applied brakes which are ap-
proved for the use with such rectifiers. Other use is only permitted with the approval of INTORQ.
Once a set overexcitation time has elapsed, the bridge/half-wave rectifiers switch over from bridge rectifica-
tion to half-wave rectification. Depending on the design of the load, an improvement of the switching behav-
iour or a reduction in performance is possible.