11
2 Hang the fan in the installation plate, making sure that the
mount lines up properly with the notch (see Fig.: circle).
3 Electrical connection
Colour coding:
Green-yellow (
I
): PE conductor
Blue (
II
): Neutral
conductor
Brown (
III
):
Current-carrying wire (also: black)
Connect the electrical wires
Step 1: Connect the PE conductor to the lamp-wire
connector (
I
).
Step 2: Connect the blue wire (N) (
II
).
Step 3: Connect the brown wire (L) (
III
).
Connect the cable plug
Connect the cable plugs of the two PE conductors of the
fan with the sockets on the installation plate.
Then connect the wide cable plug of fan to the socket on
the installation plate.
4 Snap the casing (A) onto the installation plate: insert it into
the two adjacent bearings and snap it into the opposing
spring-loaded bearing (click!).
5 Insert the halogen bulbs into the lamp: place the bulbs
into the round grooves with light pressure, then turn
clockwise until tight.
6 Switch on the power supply.
DANGER
: The electrical connection may only
be performed by a qualified electrician!
Failure to follow these instructions presents a life-
threatening risk of electric shock!!
( I )
(II)
(III)
1
2
3
“KLICK”
A
NOTE:
Avoid touching the halogen bulbs with
your fingers. Use a clean cloth or cloth gloves when
inserting the bulbs
IB_KH1150_E2731_UK_V1.qxd 15.01.2007 14:47 Uhr Seite 11
Summary of Contents for LERVIA KH 1150
Page 2: ... Ceiling Fan KH 1150 Operating Manual IB_KH1150_E2731_UK_V1 qxd 15 01 2007 14 46 Uhr Seite 2 ...
Page 3: ...IB_KH1150_E2731_UK_V1 qxd 15 01 2007 14 47 Uhr Seite 3 ...
Page 4: ...A G F D E C B H I J K L IB_KH1150_E2731_UK_V1 qxd 15 01 2007 14 47 Uhr Seite 4 ...
Page 17: ... 15 IB_KH1150_E2731_UK_V1 qxd 15 01 2007 14 47 Uhr Seite 15 ...