11
USER MANUAL
Micro inverters are arranged by their micro inverter table number
(where empty places are left out). the meaning of the numbers,
lines, and colours is the same as in the Physical layout.
4.2 Matrix layout
Figure 12: Matrix layout
MAiN PAgE
current status and the last measurements for each micro
inverter are gathered in the table. if you click on an alarm iD, you
4.3 Panel statistics
Figure 13: Panel statistics
Measurement
Interpretation
Expected values
Panel iD
Panel iD
-
Micro inverter iD
Micro inverter iD
-
time
Measurement timestamp
-
Status
Status
on
Hw ver.
Micro inverter hardware version
-
Sw ver.
Micro inverter software version
-
Max Power
Maximal output power of the micro inverter
Depends on user settings
cos phi
Ratio of the real and apparent power
Depends on user settings
Freq.
Frequency
Approximately 50hz.
Dc-Dc t.
temperature at the Dc side of the micro inverter
Depends on the mounting frame heat dissipation
Dc-Ac t.
temperature at the Ac side of the micro inverter
Depends on the mounting frame heat dissipation
Sec Dc volt.
Voltage at the secondary Dc side
Approximately 400V
Alarm iD
Alarm iD
0 (For detailed description of alarm iD see the
Micro inverter user manual.)
will be redirected to the Alarm history. the interpretation of the
measurements can be found in the next table.