Online commands
Leuze electronic
BCL 600i/BCL 601i
58
11
Online commands
Online commands can be used to send commands directly to the device for control and configuration.
For this purpose, the device must be connected to a host- or service computer via the interface. The
commands described can be sent either via the host or the service interface.
Online commands
With the commands, you can:
• control/decode.
• read/write/copy parameters.
• carry out an automatic configuration.
• teach-in/set reference codes.
• call up error messages.
• call up statistical device information.
• carry out a software reset in order to reinitialize the device.
Syntax
Online commands consist of one or two ASCII characters followed by command parameters. No separa
-
tion characters may be entered between the command and the command parameter(s). Both small and
capitalized letters can be used.
Example:
Most online commands are acknowledged by the device and any requested data returned. For commands
that are not acknowledged, command execution can be observed or monitored directly on the device.
11.1 General online commands
Software version number
Command CA:
autoConfig function
Par:
Activation
Transmitted is:
CA+
Command
V
Description
Requests device version information
Parameter
No
Acknowledgment
BCL 600i SM 100 V 1.3.8 2008-02-15
The first line contains the device type, followed by the device version number
and version date. (The data which is actually displayed may vary from the val
-
ues given here.)
This command returns the major release number of the software packet. This major release
number also appears on the display during start-up.
This command can be used to check whether the connected host or service computer is properly
connected and configured. If you do not receive an acknowledgment, please check interface
connections, protocol and service switches.