Online commands
Leuze electronic
BCL 600i/BCL 601i
64
11.3 Online commands for the parameter set operations
Copying parameter set
Command
PC
Description
This command can only be used to copy parameter sets in their entirety. This
can be used to replicate the three parameter sets default, permanent and
operating parameters on the basis of one another. In addition, this command
also be used to restore the factory settings.
Parameter
PC<Source type><Target type>
<Source
type>
Parameter data set that is to be copied,
unit [dimensionless]
0
Parameter data set in permanent memory
2
Default or factory parameter set
3
Operating parameter data set in volatile memory
<Target
type>
Parameter set into which the data is to be copied,
unit [dimensionless]
0
Parameter data set in permanent memory
3
Operating parameter data set in volatile memory
Permissible combinations here include:
03
Copying the data set from the permanent memory to the operat
-
ing parameter data set
30
Copying the operating parameter data set to the permanent
parameter set memory
20
Copying the default parameters to the permanent memory and to
the main memory
Acknowledgment
PS=<aa>
<aa>
Status acknowledgment,
unit [dimensionless]
00
Ok
01
Syntax error
02
Impermissible command length
03
Reserved
04
Reserved
05
Reserved
06
Impermissible combination, source type - target type