Online commands
Leuze electronic
BCL 600i/BCL 601i
65
Requesting parameter data set from device
Command
PR
Description
The parameters of the device are grouped together in a parameter set and
permanently stored in memory. There is one parameter set in permanent
memory and one operating parameter set in volatile memory; in addition,
there is a default parameter set (factory parameter set) for initialization. This
command can be used to edit the first two parameter sets (in permanent and
volatile memory). A check sum can be used for reliable parameter transfer.
Parameter
PR<BCC type><PS type><Address><Data length>[<BCC>]
<BCC type>
Check-digit function during transmission,
unit [dimensionless]
0
Not used
3
BCC mode 3
<PS type>
Memory from which the values are to be read,
unit [dimensionless]
0
Parameter values stored in the flash memory
1
Reserved
2
Default values
3
Operating values in RAM
<Address>
Relative address of the data within the data set
aaaa Four-digit,
unit [dimensionless]
<Data length> Length of the parameter data to be transferred
bbbb
Four-digit,
unit [length in bytes]
<BCC>
Check sum calculated as specified under BCC type