Configuration
Leuze
electronic
70
Technical Description BCL 80
Leuze electronic
Framing Protocol
The following parameters for transfer to the host can be set in the menu ’Framing Protocol’:
• Prefix 1 (title header character)
• Prefix 2 (title header character)
• Postfix 1 (title footer character)
• Postfix 2 (title footer character)
• Address Format
• BCC Mode (Block Check Character)
More detailed information concerning the BCC modes is available on request.
Protocol
No protocol
Protocol Frame
Protocol frame with acknowledge
3964 / RK 512 Protocol
multiNet Plus slave
Handshake Mode
No Handshake
RTS
RTS / CTS
RTS / CTS ; TX active
Half duplex
XON / XOFF
Parameter
Valid range of values
Default
Prefix 1
00h … FFh
[02h]
Prefix 2
00h … FFh
[00h]
Postfix 1
00h … FFh
[0Dh]
Postfix 2
00h … FFh
[0Ah]
Address Format
No Address
Binary address
ASCII address
BCC-Mode
No BCC
BCC mode 1
BCC mode 2
BCC mode 3
Note!
If the BCL 80 should operate ’stand alone’ as a slave in the multiNet, then the following set-
tings are required:
Data format: multiNet
mode
Baud rate: 57600
baud
Protocol: MultiNet
Plus
slave
Handshake: none
Address format: ASCII address
Parameter
Valid range of values
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com