Configuration
Leuze
electronic
116
Technical Description BCL 90
Leuze electronic
Software reset
9.2.2 ’Online’ Command for System Control
Activate sensor input 1
Deactivate sensor input 1
Copy parameter set
Command
’H’
Description
Carries out a software reset. The device is restarted and reinitial-
ised, leaving it in the same state as when the supply voltage is
switched on.
Parameter
no
Acknowledgement
’S’ (start signal)
Command
’+’
Description
The command activates decoding.
Parameter
no
Acknowledgement
no
Command
’-’
Description
The command deactivates decoding.
Parameter
no
Acknowledgement
no
Command
’PC’
Description
The command copies complete parameter sets.
Parameter
’20’
copy standard parameters from the FLASH into
the EEPROM and RAM and initialise all relevant
functions
Acknowledgement
’PSx’
x: status
’000’
command successfully executed
’001’
general error in loading the default values or in
writing in the internal EEPROM parameter memory