Leuze
electronic
Device Description
Leuze electronic
Technical description BCL 90
23
T
N
T 35/
7-
24V
Networking via multiNet plus
Figure 3.5: Networking possibilities via multiNet plus (BCL 90)
Two-wire RS 485
The Leuze multiNet plus is optimised for fast transmission of scanner data to a primary host computer.
Physically, it consists of a two-wire RS 485 interface controlled by a software protocol, the multiNet
plus protocol. This makes wiring the network easy and inexpensive as slaves are connected to one
another in parallel.
Interface module
Shielded, twisted pair conductors should be used for the multiNet. This allows a total network length
of up to 1200 m. The network is connected to the primary computer via the host interface of MA 31,
which can be equipped with four different physical interface modules. The available options are mod-
ules for RS 422, RS 232, TTY or RS 485.
Slave 1
BCL 90 / MA 90
Slave 2
BCL 90 / MA 90
Slave 3
BCL 90 / MA 90
RS 232
RS 422
RS 485
or
TTY
Host
(PLC, process, etc.)
- Backup
- Parameter
Voltage supply
Network master
multiNet plus
MA 30/31
RS 485