Technical Data
Leuze
electronic
28
Technical Description BCL 90
Leuze electronic
Function switched inputs
6 ("SE 1 … SE 6")
- with opto-coupler, U
emax
= +30 V, polarity-proof,
can be connected to p-n-p outputs
- "SE 1" (reading cycle): max. internal delay time 30 ms,
reduced max. 2 … 6 ms
- "SE 2 … SE 6": focus position switching,
IN 3 and IN 4: selectable function
int. delay time max. 30 ms
Function switched outputs
4 ("SWO 1" … "SWO 4")
- p-n-p, short-circuit proof, adjustable pulse duration
(statical, resolution 10 … 990 ms or 100 … 9900 ms)
- function of the result status indication selectable
Electrical connections
1 x 15-pin D-Sub-HD device plug,
1 x 15-pin D-Sub-HD device socket
Operating voltage/
power consumption
DC 18 … 30 V/ typically 9 W, max. 16 W
Housing
Aluminium die-cast, no silicone used in the exterior materials
Type of protection/ safety class IP 65
3)
(acc. to DIN 40 050)/ Class 3 (acc. to VDE 0106/IEC 1010-
1)
EMC/ vibration/
shock testing
acc. to IEC 801/ acc. to IEC 68-2-6 Test FC/ acc. to IEC 68-2-27
Test EA
Weight
around 1.5 kg
Operating ambient/
storage temperature
0 … +40 °C/ –40 … +70 °C
Max. relative air humidity
90%, non-condensing
1)
In read operation under the clocking types "switched input sensor" and "serial interface"
2)
Scan gate time: time window of code evaluation generated internally through the reading cycle
3)
Including plug cover or plug cover with parameter memory
Model
BCL 90 CAT M 100
Medium Density
BCL 90 CAT N 100
High Density
BCL 90 CAT F 100
Low Density
Table 4.1: Technical specifications BCL 90 CAT M 100 / N 100 / F 100 (Cont.)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com