Leuze
electronic
Technical Data
Leuze electronic
Technical Description BCL 90
29
T
N
T 35/
7-
24V
4.1.2 Data Sheet BCL 90 CAT OM 100, BCL 90 CAT ON 100, BCL 90 CAT OF 100
Technical data same as BCL 90 CAT M/N/F 100 except for the following deviations:
Table 4.2: Technical specifications BCL 90 CAT OM 100 / ON 100 / OF 100
4.1.3 Data Sheet BCL 90 CAT M 100H, BCL 90 CAT N 100H, BCL 90 CAT F 100H
Technical data same as BCL 90 CAT M/N/F 100 except for the following deviations:
Table 4.3: Technical specifications BCL 90 CAT M 100H / N 100H / F 100H
Model
BCL 90 CAT OM 100 /BCL 90 CAT ON 100 /BCL 90 CAT OF 100
Type
Line scanner with oscillating mirror
Reading window
lateral
Light exit
at an angle of 105°
Focus trigger
additionally: oscillating mirror reversal points
Useful opening angle
max. 50°
Oscillating mirror functions stationary, oscillating (variable or predefined amplitude), one-shot
1)
Oscillation frequency
0.2 … 4 Hz
Max. deflection angle
max. ± 20° (± 40 CW), adjustable through the software
DOF
see reading field diagram starting from page 40
Deflection widths
see Figure 4.15, on page 46
Operating voltage/
power consumption
DC 18 … 30 V/ typically 9 W, max. 18 W
Weight
around 2.2 kg
1)
One-shot: single oscillation per reading cycle (starting position and speed for
forward and return phase selectable)
Model
BCL 90 CAT M 100 H / BCL 90 CAT N 100 H / BCL 90 CAT F 100 H
Type
Line scanner with heater
Switch-on behaviour/
temperature variation
see “Optional heater” on page 21
Switch-on delay
35 … 40 min (for DC 24 V and min. ambient temp. of –35°)
Operating voltage
DC 24 V +20% / –0%
Power consumption
typically 75 W, max. 90 W
Required
core cross-section
at least 0.75 mm² (for operating voltage supply)
Weight
around 1.5 kg
Operating ambient/
storage temperature
–35 … +35 °C / –20 … +70 °C