Electrical Connection
Leuze electronic
Technical Description BCL 90
89
T
N
T 35/
7-
24V
7.5.4 Connect the BCL 90 host interface
Figure 7.2: Circuitry of the host interface
1.
Connect the host interface of the BCL acc. to EMC via shielded cables to the host. At the same
time, keep the maximum cable lengths in mind (see Table 7.6, on page 83).
2.
Mount the shielding on one end
In the base setting, the BCL communicates with the host via the host interface of which the parameters
are listed in Table 7.14.
Table 7.14:Communication parameter of the host interface (base setting)
Damage to the interface module!
Incorrect connection of the host interface may lead to damage to electronic components in
the BCL. This also applies to the adjustment of the host interface connection in the connec-
tor units (configuration).
• Correctly connect the host interface acc. to Figure 7.2.
• Carefully check the circuitry before switching on the BCL.
Parameter
Value
Type
RS 232
Data transmission rate
9600 bit/s
Data bit/parity
8/none
Stop bit
1
Protocol
Prefix 1: STX
Postfix 1: CR
Postfix 2: LF
Notice!
For connecting the host interface via the connector unit MA 90 see data sheet MA 90.
RxD
TxD
GND
RD+
RD—
TD+
TD—
GND
TxD
RxD
GND
TD+
TD—
RD+
RD—
GND
7
9
5
(3)
(2)
(5)
6
7
8
9
5
Host
Host
BCL
BCL
RS-232
RS-422
()=9-pin D-Sub plug on the PC